Experimental Study and Quantitative Analysis of the Physical Parameters of the Proton Therapy Scanning Beam Delivery System

The development of proton therapy techniques imposes strict requirements for the accuracy of proton beam delivery. Existing methods for determining the planning target volume allow one to take into account only the influence of patient positioning errors before the start of irradiation. In this paper, the results of work on taking into account proton therapy system beam delivery errors for determining the planning target volume are presented. The technique for measuring the proton beam parameters and analyzing the measurement results is described. The calculation of the minimum required margin from the clinical target volume is carried out to guarantee its irradiation, taking into account the errors in beam delivery by the proton therapy system.

Authors

Institutions

Publication Details

Journal
Vestnik Moskovskogo Universiteta Seriya 3 Fizika Astronomiya
Published
2024-10-14
DOI
https://doi.org/10.55959/msu0579-9392.79.2440702
Primary Topic
Advanced Radiotherapy Techniques
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Experimental Study and Quantitative Analysis of the Physical Parameters of the Proton Therapy Scanning Beam Delivery System

М. А. Белихин, A. M. Demidova, V.A. Kiselev, A. P. Chernyaev et al.
Vestnik Moskovskogo Universiteta Seriya 3 Fizika Astronomiya
Advanced Radiotherapy Techniques
article

Experimental Study and Quantitative Analysis of the Physical Parameters of the Proton Therapy Scanning Beam Delivery System

М. А. Белихин, A. M. Demidova, V.A. Kiselev, A. P. Chernyaev, S. E. Gritsenko, Yu. D. Udalov
article en

Abstract

The development of proton therapy techniques imposes strict requirements for the accuracy of proton beam delivery. Existing methods for determining the planning target volume allow one to take into account only the influence of patient positioning errors before the start of irradiation. In this paper, the results of work on taking into account proton therapy system beam delivery errors for determining the planning target volume are presented. The technique for measuring the proton beam parameters and analyzing the measurement results is described. The calculation of the minimum required margin from the clinical target volume is carried out to guarantee its irradiation, taking into account the errors in beam delivery by the proton therapy system.

Vestnik Moskovskogo Universiteta Seriya 3 Fizika Astronomiya(№4_2024)
P.N. Lebedev Physical Institute of the Russian Academy of Sciences (RU), Lomonosov Moscow State University (RU), Moscow State University (TJ)
Openalex Percentile: Top 74%
Advanced Radiotherapy Techniques
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Experimental Study and Quantitative Analysis of the Physical Parameters of the Proton Therapy Scanning Beam Delivery System — М. А. Белихин, A. M. Demidova, et al. · Vestnik Moskovskogo Universiteta Seriya 3 Fizika Astronomiya (2024) | TGRS Research Map | TGRS