An in vitro wear behavior analysis of polymer composite for biomedical application

The tribological performance of basalt fiber reinforced PEEK material especially used as a biomaterial in many biomedical and dental applications is of interest. The specimens of three different weight fractions of PEEK and basalt fiber are fabricated as per ASTM G99 standards. The prepared specimens are having PEEK and basalt fiber in the weight percentage of 90:10, 80:20 and 70:30 ratio and named as PBC 1, PBC 2 and PBC 3 respectively. The specimens are subjected to pin-on-disc test using EN31 steel as the sliding disc material. The hardness of PBC 2 specimen shows a better value of 50.74 HRB. Wear resistance is comparatively less when Basalt weight percentage increases from 10% to 20%, but further increase of basalt fiber in the composite, the wear resistance drops down. Similarly, the COF values also noted high for PBC 2 compared to pure PEEK, PBC 1 and PBC 3 composites. PBC 2 sample is found to be better with high wear resistance.

Authors

Institutions

Publication Details

Journal
Bioinformation
Published
2024-08-31
DOI
https://doi.org/10.6026/973206300200950
Primary Topic
Tribology and Wear Analysis
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

An in vitro wear behavior analysis of polymer composite for biomedical application

Debashish Debnath, Padmapriya Mahalingam, Queen Alice Arul, Arul Jeyakumar Arputham
Bioinformation
Tribology and Wear Analysis
article

An in vitro wear behavior analysis of polymer composite for biomedical application

Debashish Debnath, Padmapriya Mahalingam, Queen Alice Arul, Arul Jeyakumar Arputham
article en

Abstract

The tribological performance of basalt fiber reinforced PEEK material especially used as a biomaterial in many biomedical and dental applications is of interest. The specimens of three different weight fractions of PEEK and basalt fiber are fabricated as per ASTM G99 standards. The prepared specimens are having PEEK and basalt fiber in the weight percentage of 90:10, 80:20 and 70:30 ratio and named as PBC 1, PBC 2 and PBC 3 respectively. The specimens are subjected to pin-on-disc test using EN31 steel as the sliding disc material. The hardness of PBC 2 specimen shows a better value of 50.74 HRB. Wear resistance is comparatively less when Basalt weight percentage increases from 10% to 20%, but further increase of basalt fiber in the composite, the wear resistance drops down. Similarly, the COF values also noted high for PBC 2 compared to pure PEEK, PBC 1 and PBC 3 composites. PBC 2 sample is found to be better with high wear resistance.

BioinformationVol. 20(8)
Tamil Nadu Government Dental College and Hospital (IN), SRM University (IN), All India Institute of Medical Sciences (IN), University of Kalyani (IN)
Openalex Percentile: Top 81%
Tribology and Wear Analysis
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

An in vitro wear behavior analysis of polymer composite for biomedical application — Debashish Debnath, Padmapriya Mahalingam, et al. · Bioinformation (2024) | TGRS Research Map | TGRS