The CRILIN calorimeter: gamma radiation resistance of crystals and SiPMs

Abstract The Crilin calorimeter is a semi-homogeneous calorimetric system based on Lead Fluoride (PbF 2 ) crystals with UV-extended Silicon Photomultipliers (SiPMs) proposed for the Muon Collider. This study investigates the radiation resistance of crystals and SiPMs, subjected to 10 kGy gamma irradiation, equivalent to a 10-year service life in the Muon Collider. Our findings indicate that while PbF 2 crystals exhibit a decrease in transmittance post-irradiation with partial recovery over time, the alternative PbWO 4 -Ultra Fast (PWO-UF) demonstrates exceptional radiation hardness, maintaining stable transmittance. SiPMs showed an increase in dark current and breakdown voltage post-irradiation, with less degradation observed in the SiPM biased during the exposure to radiation compared to the unbiased component. These results underscore the viability of PbF 2 for radiation-tolerant calorimeters, though improvements in production homogeneity are needed. The superior performance of PWO-UF crystals suggests they are a promising alternative for high-radiation applications, but their higher cost must be carefully considered.

Authors

Institutions

Publication Details

Journal
Journal of Instrumentation
Published
2024-10-01
DOI
https://doi.org/10.1088/1748-0221/19/10/p10016
Citations
4
Primary Topic
Radiation Detection and Scintillator Technologies
Type
article
Field-Weighted Citation Impact
2.43
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

The CRILIN calorimeter: gamma radiation resistance of crystals and SiPMs

D. Paesani, B. D'Orsi, Ilaria Di Sarcina, E. Di Meco et al.
4 citations
Journal of Instrumentation
Radiation Detection and Scintillator Technologies
2.43
article

The CRILIN calorimeter: gamma radiation resistance of crystals and SiPMs

D. Paesani, B. D'Orsi, Ilaria Di Sarcina, E. Di Meco, Alessia Cemmi, A. Verna, J. Scifo, I. Sarra, E. Diociaiuti, M. Moulson
article en
4 citations

Abstract

Abstract The Crilin calorimeter is a semi-homogeneous calorimetric system based on Lead Fluoride (PbF 2 ) crystals with UV-extended Silicon Photomultipliers (SiPMs) proposed for the Muon Collider. This study investigates the radiation resistance of crystals and SiPMs, subjected to 10 kGy gamma irradiation, equivalent to a 10-year service life in the Muon Collider. Our findings indicate that while PbF 2 crystals exhibit a decrease in transmittance post-irradiation with partial recovery over time, the alternative PbWO 4 -Ultra Fast (PWO-UF) demonstrates exceptional radiation hardness, maintaining stable transmittance. SiPMs showed an increase in dark current and breakdown voltage post-irradiation, with less degradation observed in the SiPM biased during the exposure to radiation compared to the unbiased component. These results underscore the viability of PbF 2 for radiation-tolerant calorimeters, though improvements in production homogeneity are needed. The superior performance of PWO-UF crystals suggests they are a promising alternative for high-radiation applications, but their higher cost must be carefully considered.

Journal of InstrumentationVol. 19(10)
National Agency for New Technologies, Energy and Sustainable Economic Development (IT), Istituto Nazionale di Fisica Nucleare, Laboratori Nazionali di Frascati (IT)
Openalex Percentile: Top 11%
Radiation Detection and Scintillator Technologies
2.43
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.