Straightforward, Highly Useful, Innovative and Cost-Effective Method with Potential to Improve Personalized Diagnosis: Sectioning of Prostatectomy Specimen with a Single Blade

Abstract Introduction/Objective There is potential for devices with an adjustable base and a single blade to precisely cut parallel slices of a prostatectomy specimen at a set preferred thickness to improve pathology practice by standardizing the tissue for histological review, allowing for precise punch biopsies of the slices for molecular diagnostics for biobanking and personalized therapy. The current standard method of sectioning the prostate involves serially sectioning the prostatectomy specimen by hand with a sharp long knife, leading to uneven sections. Methods/Case Report A device with an adjustable base was developed at a regional Veteran Affairs Medical Center (VAMC) that consists of two sets of multiple, vertically arranged parallel and flat bars measuring 10 cm in height, 1.5 cm in width and 0.3 cm in thickness spaced 0.4 cm from each other, resembling a comb with flat teeth. After inking, orientation, and removal of the seminal vesicles and apex and base margins, the prostatectomy specimen is immobilized between the two combs and sliced in parallel from apex to base to produce parallel consistent prostate slices. The ability to obtain punch biopsies from precise areas of the prostate was reviewed. Results (if a Case Study enter NA) The device results in uniform 4 mm thick oriented smooth specimen slices of good quality with minimal distortion. The device allows for the obtaining of punch biopsies taken at precise locations of the prostate corresponding to specific imaging locations (highly useful for biobanking or obtaining diagnostic tissue for molecular diagnostics for personalized therapy). The adjustable nature of the device and single blade gives the device flexibility in the specimen. Conclusion This device with an adjustable base and single blade allows for safe and precise parallel slicing. This is highly useful obtaining diagnostic standardized tissue, for obtaining biobank specimens and for obtaining material of precise location for molecular studies to guide the personalized therapy of tumors.

Authors

Institutions

Publication Details

Journal
American Journal of Clinical Pathology
Published
2024-10-01
DOI
https://doi.org/10.1093/ajcp/aqae129.211
Primary Topic
Prostate Cancer Diagnosis and Treatment
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Straightforward, Highly Useful, Innovative and Cost-Effective Method with Potential to Improve Personalized Diagnosis: Sectioning of Prostatectomy Specimen with a Single Blade

Sanjay Gandhi, J M Petersen, Darshana Jhala
American Journal of Clinical Pathology
Prostate Cancer Diagnosis and Treatment
article

Straightforward, Highly Useful, Innovative and Cost-Effective Method with Potential to Improve Personalized Diagnosis: Sectioning of Prostatectomy Specimen with a Single Blade

Sanjay Gandhi, J M Petersen, Darshana Jhala
article en

Abstract

Abstract Introduction/Objective There is potential for devices with an adjustable base and a single blade to precisely cut parallel slices of a prostatectomy specimen at a set preferred thickness to improve pathology practice by standardizing the tissue for histological review, allowing for precise punch biopsies of the slices for molecular diagnostics for biobanking and personalized therapy. The current standard method of sectioning the prostate involves serially sectioning the prostatectomy specimen by hand with a sharp long knife, leading to uneven sections. Methods/Case Report A device with an adjustable base was developed at a regional Veteran Affairs Medical Center (VAMC) that consists of two sets of multiple, vertically arranged parallel and flat bars measuring 10 cm in height, 1.5 cm in width and 0.3 cm in thickness spaced 0.4 cm from each other, resembling a comb with flat teeth. After inking, orientation, and removal of the seminal vesicles and apex and base margins, the prostatectomy specimen is immobilized between the two combs and sliced in parallel from apex to base to produce parallel consistent prostate slices. The ability to obtain punch biopsies from precise areas of the prostate was reviewed. Results (if a Case Study enter NA) The device results in uniform 4 mm thick oriented smooth specimen slices of good quality with minimal distortion. The device allows for the obtaining of punch biopsies taken at precise locations of the prostate corresponding to specific imaging locations (highly useful for biobanking or obtaining diagnostic tissue for molecular diagnostics for personalized therapy). The adjustable nature of the device and single blade gives the device flexibility in the specimen. Conclusion This device with an adjustable base and single blade allows for safe and precise parallel slicing. This is highly useful obtaining diagnostic standardized tissue, for obtaining biobank specimens and for obtaining material of precise location for molecular studies to guide the personalized therapy of tumors.

American Journal of Clinical PathologyVol. 162(Supplement_1)
University of Pennsylvania (US)
Openalex Percentile: Top 67%
Prostate Cancer Diagnosis and Treatment
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.