LOADS ON SUBMERGED WALLS OF PROTECTIVE STRUCTURES

The intensification of military operations on the territory of Ukraine, which are accompanied by missile attacks and bombing of territories, requires the use of reliable protective structures. Modern codes require the provision of each new building with storage facilities that guarantee the safety of life and health of citizens, so the correct determination of all loads on the structural elements of protective structures is an urgent issue. Taking into acoount the fact that the previous codes were somewhat outdated and had limited access for a long time, a significant event was the adoption in 2023 of new codes for the design of protective structures of civil defence. The main requirements and recommendations of SBC B.2.2-5:20023 were taken into account when conducting research on determining the loads on buried walls of bomb shelters. Such structures, as we know, perceive a constant load from the lateral pressure of the soil, which during an explosion is supplemented by an episodic load from the action of an air wave. Modern specialized literature contains rather limited information on scientific research and development in the field of design of protective structures. An actual issue is also the study of the influence of determining factors on the intensity of the load on the walls of buried protective structures and the possibility of its adjustment in order to reduce it. Taking into account the nature of the distribution of loads on the underground walls of bomb shelters, a dependence was obtained to determine the resulting active pressure and quasi-static load caused by the action of an air wave. The pressures from the soil and the blast wave at different orientations of the contact wall and for different types of soil environment were studied. The loads in contact of a smooth and rough wall with sandy, sandy and loamy soils with different indicators of physical and mechanical characteristics were considered. The obtained results indicate a significant influence of the geometric parameters of the wall and the features of the contact soil on the resulting pressure, which can vary depending on the studied factors by 10-20%, which indicates the possibility of reducing the load on protective structures, operating with the considered indicators.

Authors

Publication Details

Journal
Modern construction and architecture
Published
2024-09-30
DOI
https://doi.org/10.31650/2786-6696-2024-9-105-113
Primary Topic
Structural Integrity and Reliability Analysis
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

LOADS ON SUBMERGED WALLS OF PROTECTIVE STRUCTURES

I.V. Voitenko
Modern construction and architecture
Structural Integrity and Reliability Analysis
article

LOADS ON SUBMERGED WALLS OF PROTECTIVE STRUCTURES

I.V. Voitenko
article en

Abstract

The intensification of military operations on the territory of Ukraine, which are accompanied by missile attacks and bombing of territories, requires the use of reliable protective structures. Modern codes require the provision of each new building with storage facilities that guarantee the safety of life and health of citizens, so the correct determination of all loads on the structural elements of protective structures is an urgent issue. Taking into acoount the fact that the previous codes were somewhat outdated and had limited access for a long time, a significant event was the adoption in 2023 of new codes for the design of protective structures of civil defence. The main requirements and recommendations of SBC B.2.2-5:20023 were taken into account when conducting research on determining the loads on buried walls of bomb shelters. Such structures, as we know, perceive a constant load from the lateral pressure of the soil, which during an explosion is supplemented by an episodic load from the action of an air wave. Modern specialized literature contains rather limited information on scientific research and development in the field of design of protective structures. An actual issue is also the study of the influence of determining factors on the intensity of the load on the walls of buried protective structures and the possibility of its adjustment in order to reduce it. Taking into account the nature of the distribution of loads on the underground walls of bomb shelters, a dependence was obtained to determine the resulting active pressure and quasi-static load caused by the action of an air wave. The pressures from the soil and the blast wave at different orientations of the contact wall and for different types of soil environment were studied. The loads in contact of a smooth and rough wall with sandy, sandy and loamy soils with different indicators of physical and mechanical characteristics were considered. The obtained results indicate a significant influence of the geometric parameters of the wall and the features of the contact soil on the resulting pressure, which can vary depending on the studied factors by 10-20%, which indicates the possibility of reducing the load on protective structures, operating with the considered indicators.

Modern construction and architecture(9)
Sustainable cities and communities
Openalex Percentile: Top 82%
Structural Integrity and Reliability Analysis
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.