Challenges of forward osmosis desalination processes using hydrogels as draw agents

The present study aims to investigate the properties, identification, and comprehension of the obstacles encountered in the forward osmosis process when utilizing a hydrogel drawing agent (FO-HG). Furthermore, a comparison is made between the FO-HG system and conventional forward osmosis systems employing a salt solution drawing agent. The comparison and evaluation of the swelling process of hydrogel and the kinetics of water penetration are conducted in both un-constrained and constrained states. Furthermore, the investigation and analysis are carried out to determine the presence or absence of internal concentration polarization (ICP) and external concentration polarization (ECP) phenomena. These phenomena are studied in situations with and without mixing, as well as in different orientations of the membrane (FO-mode and PRO-mode). The impact of these phenomena on the water flux of the systems FO-HG and FO-NaCl is also examined. An evaluation is conducted to determine the influence of the amount and size of hydrogel used as a draw agent in the FO-HG system on the water flux. The results of the study reveal that smaller hydrogel particles in the FO-HG system exhibit a higher flux compared to larger particles. Additionally, it is observed that the water flux in PRO-mode is unexpectedly higher when salt water is used as feed solution. This phenomenon can be ascribed to a counter-osmotic effect, originating from the FO state. Despite the high water absorption capacity of hydrogel and its potential as an ideal drawing agent in the forward osmosis process, the results demonstrate that the flux of the FO-HG system is inferior to that of the FO-NaCl system. Finally, the focus is on resolving the low flux issue by suggesting a process involving multiple cycles throughout day and night. We investigate the influence of hydrogel particle size, membrane surface, hydrogel layer thickness, as well as swelling and deswelling time in one cycle. The swelling time displays a peak at an optimal absorption duration, while the deswelling time does not show a similar optimal point, highlighting the difference between swelling and deswelling phenomena. Therefore, the hydrogels' high absorption capacity alone is insufficient for achieving desalination success. The research findings emphasize the high importance of synthesis of a membrane with minimal resistance, enabling a high water flux and suitable selectivity. • Counter-osmotic effect plays an important role in forward-osmosis water flux. • To address this challenge, we focus on a hydrogel drawing agent. • Increasing the hydrogel quantity and mesh size increases the water flux. • Running the osmotic system in a multicyclic process also enhances the water flux. • Correlation between hydrogel-draw water flux and hydrogel swelling time displays a peak.

Authors

Institutions

Publication Details

Journal
Journal of Membrane Science
Published
2024-10-16
DOI
https://doi.org/10.1016/j.memsci.2024.123408
Citations
12
Primary Topic
Membrane Separation Technologies
Type
article
Field-Weighted Citation Impact
2.42

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Challenges of forward osmosis desalination processes using hydrogels as draw agents

Amir Jangizehi, Hassan Salehi, Christoph Bantz, Michael Maskos et al.
12 citations
Journal of Membrane Science
Membrane Separation Technologies
2.42
article

Challenges of forward osmosis desalination processes using hydrogels as draw agents

Amir Jangizehi, Hassan Salehi, Christoph Bantz, Michael Maskos, Sebastian Seiffert, Alireza Shakeri, Seyed Abdollatif Hashemifard, Dhiyaa A. Hussein Al-Timimi, Qusay F. Alsalhy, Mohammad Ali Ghanavatyan
article en
12 citations

Abstract

The present study aims to investigate the properties, identification, and comprehension of the obstacles encountered in the forward osmosis process when utilizing a hydrogel drawing agent (FO-HG). Furthermore, a comparison is made between the FO-HG system and conventional forward osmosis systems employing a salt solution drawing agent. The comparison and evaluation of the swelling process of hydrogel and the kinetics of water penetration are conducted in both un-constrained and constrained states. Furthermore, the investigation and analysis are carried out to determine the presence or absence of internal concentration polarization (ICP) and external concentration polarization (ECP) phenomena. These phenomena are studied in situations with and without mixing, as well as in different orientations of the membrane (FO-mode and PRO-mode). The impact of these phenomena on the water flux of the systems FO-HG and FO-NaCl is also examined. An evaluation is conducted to determine the influence of the amount and size of hydrogel used as a draw agent in the FO-HG system on the water flux. The results of the study reveal that smaller hydrogel particles in the FO-HG system exhibit a higher flux compared to larger particles. Additionally, it is observed that the water flux in PRO-mode is unexpectedly higher when salt water is used as feed solution. This phenomenon can be ascribed to a counter-osmotic effect, originating from the FO state. Despite the high water absorption capacity of hydrogel and its potential as an ideal drawing agent in the forward osmosis process, the results demonstrate that the flux of the FO-HG system is inferior to that of the FO-NaCl system. Finally, the focus is on resolving the low flux issue by suggesting a process involving multiple cycles throughout day and night. We investigate the influence of hydrogel particle size, membrane surface, hydrogel layer thickness, as well as swelling and deswelling time in one cycle. The swelling time displays a peak at an optimal absorption duration, while the deswelling time does not show a similar optimal point, highlighting the difference between swelling and deswelling phenomena. Therefore, the hydrogels' high absorption capacity alone is insufficient for achieving desalination success. The research findings emphasize the high importance of synthesis of a membrane with minimal resistance, enabling a high water flux and suitable selectivity. • Counter-osmotic effect plays an important role in forward-osmosis water flux. • To address this challenge, we focus on a hydrogel drawing agent. • Increasing the hydrogel quantity and mesh size increases the water flux. • Running the osmotic system in a multicyclic process also enhances the water flux. • Correlation between hydrogel-draw water flux and hydrogel swelling time displays a peak.

Journal of Membrane ScienceVol. 714
University of Technology - Iraq (IQ), Johannes Gutenberg University Mainz (DE), University of Tehran (IR), Persian Gulf University (IR)
Bundesministerium für Bildung und Forschung
Openalex Percentile: Top 12%
Membrane Separation Technologies
2.42
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.