Prediction of bone ingrowth into a porous novel hip-stem: A finite element analysis integrated with mechanoregulatory algorithm

Bone ingrowth into a porous implant is necessary for its long-term fixation. Although attempts have been made to quantify the peri-implant bone growth using finite element (FE) analysis integrated with mechanoregulatory algorithms, bone ingrowth into a porous cellular hip stem has scarcely been investigated. Using a three-dimensional (3D) FE model and mechanobiology-based numerical framework, the objective of this study was to predict the spatial distribution of evolutionary bone ingrowth into an uncemented novel porous hip stem proposed earlier by the authors. A CT-based FE macromodel of the implant-bone structure was developed. The bone material properties were assigned based on CT grey value. Peak musculoskeletal loading conditions, corresponding to level walking and stair climbing, were applied. The geometry of the implant-bone macromodel was divided into multiple submodels. A suitable mapping framework was used to transfer maximum nodal displacements from the FE macromodel to the cut boundaries of the FE submodels. CT grey value-based bone materials properties were assigned to the submodels. Thereafter, the submodels were solved and simulations of bone ingrowth were carried out using mechanoregulatory principle. A gradual increase in the average Young's modulus, from 1200 to 1500 MPa, of the bone tissue layer was observed considering all the submodels. The distal submodel exhibited 82% of bone ingrowth, whereas the proximal submodel experienced 65% bone ingrowth. Equilibrium in the bone ingrowth process was achieved in 7 weeks postoperatively, with a notable amount of bone ingrowth that should lead to biological fixation of the novel hip stem.

Authors

Institutions

Publication Details

Journal
Proceedings of the Institution of Mechanical Engineers Part H Journal of Engineering in Medicine
Published
2024-10-01
DOI
https://doi.org/10.1177/09544119241286958
Citations
4
Primary Topic
Orthopaedic implants and arthroplasty
Type
article
Field-Weighted Citation Impact
2.29
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Prediction of bone ingrowth into a porous novel hip-stem: A finite element analysis integrated with mechanoregulatory algorithm

Bidyut Pal, Kaushik Mukherjee, Tanmoy Loha
4 citations
Proceedings of the Institution of Mechanical Engineers Part H Journal of Engineering in Medicine
Orthopaedic implants and arthroplasty
2.29
article

Prediction of bone ingrowth into a porous novel hip-stem: A finite element analysis integrated with mechanoregulatory algorithm

Bidyut Pal, Kaushik Mukherjee, Tanmoy Loha
article en
4 citations

Abstract

Bone ingrowth into a porous implant is necessary for its long-term fixation. Although attempts have been made to quantify the peri-implant bone growth using finite element (FE) analysis integrated with mechanoregulatory algorithms, bone ingrowth into a porous cellular hip stem has scarcely been investigated. Using a three-dimensional (3D) FE model and mechanobiology-based numerical framework, the objective of this study was to predict the spatial distribution of evolutionary bone ingrowth into an uncemented novel porous hip stem proposed earlier by the authors. A CT-based FE macromodel of the implant-bone structure was developed. The bone material properties were assigned based on CT grey value. Peak musculoskeletal loading conditions, corresponding to level walking and stair climbing, were applied. The geometry of the implant-bone macromodel was divided into multiple submodels. A suitable mapping framework was used to transfer maximum nodal displacements from the FE macromodel to the cut boundaries of the FE submodels. CT grey value-based bone materials properties were assigned to the submodels. Thereafter, the submodels were solved and simulations of bone ingrowth were carried out using mechanoregulatory principle. A gradual increase in the average Young's modulus, from 1200 to 1500 MPa, of the bone tissue layer was observed considering all the submodels. The distal submodel exhibited 82% of bone ingrowth, whereas the proximal submodel experienced 65% bone ingrowth. Equilibrium in the bone ingrowth process was achieved in 7 weeks postoperatively, with a notable amount of bone ingrowth that should lead to biological fixation of the novel hip stem.

Proceedings of the Institution of Mechanical Engineers Part H Journal of Engineering in MedicineVol. 238(10)
Indian Institute of Technology Delhi (IN), Indian Institute of Engineering Science and Technology, Shibpur (IN)
Life in Land
Openalex Percentile: Top 11%
Orthopaedic implants and arthroplasty
2.29
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.