Vibrational squeezing via spin inversion pulses

Magnetic resonance force microscopy (MRFM) describes a range of approaches to detect nuclear spins with mechanical sensors. MRFM has the potential to enable magnetic resonance imaging with near-atomic spatial resolution, opening up exciting possibilities in solid state and biological research. In many cases, the spin-mechanics coupling in MRFM is engineered with the help of periodic radio frequency pulses. In this paper, we report that such pulses can result in unwanted parametric amplification of the mechanical vibrations, causing misinterpretation of the measured signal. We show how the parametric effect can be canceled by auxiliary radio frequency pulses or by appropriate post-correction after careful calibration. Future MRFM measurements may even make use of the parametric amplification to reduce the impact of amplifier noise.

Authors

Institutions

Publication Details

Journal
Applied Physics Letters
Published
2024-10-14
DOI
https://doi.org/10.1063/5.0233135
Primary Topic
Mechanical and Optical Resonators
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Vibrational squeezing via spin inversion pulses

Alexander Eichler, Nils Prumbaum, Raphael Pachlatko, Christian L. Degen et al.
Applied Physics Letters
Mechanical and Optical Resonators
article

Vibrational squeezing via spin inversion pulses

Alexander Eichler, Nils Prumbaum, Raphael Pachlatko, Christian L. Degen, Marc-Dominik Krass
article en

Abstract

Magnetic resonance force microscopy (MRFM) describes a range of approaches to detect nuclear spins with mechanical sensors. MRFM has the potential to enable magnetic resonance imaging with near-atomic spatial resolution, opening up exciting possibilities in solid state and biological research. In many cases, the spin-mechanics coupling in MRFM is engineered with the help of periodic radio frequency pulses. In this paper, we report that such pulses can result in unwanted parametric amplification of the mechanical vibrations, causing misinterpretation of the measured signal. We show how the parametric effect can be canceled by auxiliary radio frequency pulses or by appropriate post-correction after careful calibration. Future MRFM measurements may even make use of the parametric amplification to reduce the impact of amplifier noise.

Applied Physics LettersVol. 125(16)
ETH Zurich (CH)
Schweizerischer Nationalfonds zur Förderung der Wissenschaftlichen Forschung
Affordable and clean energy
Openalex Percentile: Top 84%
Mechanical and Optical Resonators
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.