Photon-counting detector computed tomography: iodine density versus virtual monoenergetic imaging of pancreatic ductal adenocarcinoma

CT (EID-CT), which down-weights low-energy photons, PCD-CT counts photons equally across the entire X-ray energy spectrum, thereby increasing the iodine signal.Moreover, since the energy information of human organs primarily resides within the relatively low-energy X-ray spectrum, PCD-CT improves soft tissues contrast.Setting the low energy threshold slightly above electronic noise levels effectively minimizes noise.Additionally, PCD-CT's smaller detector pixel size, compared to EID-CT, enhances spatial resolution.Combined with improved iodine contrast, this can enhance the detectability of small objects [7,8].This may be particularly significant for detecting PDAC in the PVP, where the attenuation differences between pancreatic parenchyma and the tumor are less pronounced compared to the LAP [5].Furthermore, PCD-CT obtains spectral information from every scan because the energy of each detected photon is registered and binned.This energy information can be utilized to generate virtual monoenergetic images (VMIs), and for material decomposition, such as generating material density iodine (MD-iodine) images [9].

Authors

Institutions

Publication Details

Journal
Abdominal Radiology
Published
2024-09-26
DOI
https://doi.org/10.1007/s00261-024-04605-0
Citations
4
Primary Topic
Advanced X-ray and CT Imaging
Type
article
Field-Weighted Citation Impact
0.74

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Photon-counting detector computed tomography: iodine density versus virtual monoenergetic imaging of pancreatic ductal adenocarcinoma

Kolbeinn Halldorsson, Takayuki Suzuki, Anders Svensson, Seppo K. Koskinen et al.
4 citations
Abdominal Radiology
Advanced X-ray and CT Imaging
0.74
article

Photon-counting detector computed tomography: iodine density versus virtual monoenergetic imaging of pancreatic ductal adenocarcinoma

Kolbeinn Halldorsson, Takayuki Suzuki, Anders Svensson, Seppo K. Koskinen, Carlos Valls Duran, Zlatan Alagic, Rebecca Saeter
article en
4 citations

Abstract

CT (EID-CT), which down-weights low-energy photons, PCD-CT counts photons equally across the entire X-ray energy spectrum, thereby increasing the iodine signal.Moreover, since the energy information of human organs primarily resides within the relatively low-energy X-ray spectrum, PCD-CT improves soft tissues contrast.Setting the low energy threshold slightly above electronic noise levels effectively minimizes noise.Additionally, PCD-CT's smaller detector pixel size, compared to EID-CT, enhances spatial resolution.Combined with improved iodine contrast, this can enhance the detectability of small objects [7,8].This may be particularly significant for detecting PDAC in the PVP, where the attenuation differences between pancreatic parenchyma and the tumor are less pronounced compared to the LAP [5].Furthermore, PCD-CT obtains spectral information from every scan because the energy of each detected photon is registered and binned.This energy information can be utilized to generate virtual monoenergetic images (VMIs), and for material decomposition, such as generating material density iodine (MD-iodine) images [9].

Abdominal RadiologyVol. 50(4)
Karolinska University Hospital (SE), Karolinska Institutet (SE), Stockholm South General Hospital (SE)
Karolinska Institutet
Openalex Percentile: Top 32%
Advanced X-ray and CT Imaging
0.74
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.