An Experimental Study of an Autonomous Heat Removal System Based on an Organic Rankine Cycle for an Advanced Nuclear Power Plant

The present study focuses on the recovery of waste heat in an autonomous safety system designed for advanced nuclear reactors. The system primarily relies on passive safety condensers, which are increasingly integrated into the design of advanced Pressurized Water Reactors (PWRs). These condensers are typically immersed in large water tanks that serve as heat sinks and are placed at sufficient heights to ensure natural circulation. Such a heat removal system can operate for an extended period, depending on the size of the tank. This research is driven by the potential to recover part of the energy stored in the boiling water volume, using it as a heat source for an Organic Rankine Cycle (ORC) system via an immersed heat exchanger. The electricity generated by the ORC engine can be used to power the system components, thereby making it self-sufficient. In particular, a pump replenishes the water tank, ensuring core cooling for a duration no longer limited by the water volume in the tank. An experimental test setup, including a boiling water pool and an ORC engine with an electrical output of approximately several hundred watts, along with an immersed evaporator, was constructed at CEA (Grenoble, France). Several test campaigns were conducted on the experimental test bench, exploring different configurations: two distinct ORC working fluids, cold source temperature variation effects, and relative positioning of the submerged evaporator and heat source within the water tank impact. These tests demonstrated the reliability of the system. The results were also used to validate both the ORC condenser and evaporator models. This article presents this innovative system, which has recently been patented. Moreover, to the best of our knowledge, the investigated configuration of an ORC that includes an immersed evaporator is original.

Authors

Institutions

Publication Details

Journal
Energies
Published
2024-10-11
DOI
https://doi.org/10.3390/en17205069
Citations
3
Primary Topic
Thermodynamic and Exergetic Analyses of Power and Cooling Systems
Type
article
Field-Weighted Citation Impact
0.64

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

An Experimental Study of an Autonomous Heat Removal System Based on an Organic Rankine Cycle for an Advanced Nuclear Power Plant

Franck Morin, Guillaume Lhermet, Nadia Caney, Nicolas Tauveron et al.
3 citations
Energies
Thermodynamic and Exergetic Analyses of Power and Cooling Systems
0.64
article

An Experimental Study of an Autonomous Heat Removal System Based on an Organic Rankine Cycle for an Advanced Nuclear Power Plant

Franck Morin, Guillaume Lhermet, Nadia Caney, Nicolas Tauveron, Benoît Payebien
article en
3 citations

Abstract

The present study focuses on the recovery of waste heat in an autonomous safety system designed for advanced nuclear reactors. The system primarily relies on passive safety condensers, which are increasingly integrated into the design of advanced Pressurized Water Reactors (PWRs). These condensers are typically immersed in large water tanks that serve as heat sinks and are placed at sufficient heights to ensure natural circulation. Such a heat removal system can operate for an extended period, depending on the size of the tank. This research is driven by the potential to recover part of the energy stored in the boiling water volume, using it as a heat source for an Organic Rankine Cycle (ORC) system via an immersed heat exchanger. The electricity generated by the ORC engine can be used to power the system components, thereby making it self-sufficient. In particular, a pump replenishes the water tank, ensuring core cooling for a duration no longer limited by the water volume in the tank. An experimental test setup, including a boiling water pool and an ORC engine with an electrical output of approximately several hundred watts, along with an immersed evaporator, was constructed at CEA (Grenoble, France). Several test campaigns were conducted on the experimental test bench, exploring different configurations: two distinct ORC working fluids, cold source temperature variation effects, and relative positioning of the submerged evaporator and heat source within the water tank impact. These tests demonstrated the reliability of the system. The results were also used to validate both the ORC condenser and evaporator models. This article presents this innovative system, which has recently been patented. Moreover, to the best of our knowledge, the investigated configuration of an ORC that includes an immersed evaporator is original.

EnergiesVol. 17(20)
Commissariat à l'Énergie Atomique et aux Énergies Alternatives (FR), Laboratoire d’Innovation pour les Technologies des Énergies Nouvelles et les nanomatériaux (FR), CEA Cadarache (FR), Université Grenoble Alpes (FR)
Electricité de France
Affordable and clean energy
Openalex Percentile: Top 35%
Thermodynamic and Exergetic Analyses of Power and Cooling Systems
0.64
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.