Development of quality indicators for hypertension management at the primary health care level in South Africa

Despite many quality initiatives at the primary health care (PHC) level, little is known about the actual quality of care of patients diagnosed with hypertension in South Africa. This study aimed to develop quality indicators for hypertension management at the PHC level to improve the quality of care and patient outcomes. The RAND/UCLA Appropriateness Method, comprising two rounds, was used to develop clear, appropriate, and feasible evidence-based quality indicators for hypertension. In Round 1, a 9-point scale was used by a panel of 11 members to rate clarity and appropriateness of 102 hypertension quality indicator statements, grouped under 9 dimensions of quality hypertension management, using an online MS Excel® spreadsheet. In Round 2, 9 of the same panellists discussed all indicators and rated their appropriateness and feasibility during a remote online, interactive face-to-face MS Teams® meeting. Statements rated ≥7-9 with agreement were defined as either appropriate or feasible. The panel rated 46 hypertension quality indicator statements ≥7-9 with agreement for the appropriate and feasible measurement of the management of hypertension: monitoring (n = 16), review (n = 5), lifestyle advice (n = 9), tests (n = 7), intermediate outcomes (n = 6), referrals (n = 2) and practice/facility structures (n = 1). No indicator statements were rated both appropriate and feasible for measuring blood pressure levels and treatment. If applied, these indicators would improve monitoring and management of patients with hypertension, patient outcomes, and data quality in South Africa and result in more efficient use of scarce resources. This study can be replicable for improving care of other non-communicable diseases across Africa.

Authors

Institutions

Publication Details

Journal
Journal of Human Hypertension
Published
2024-10-14
DOI
https://doi.org/10.1038/s41371-024-00966-7
Citations
3
Primary Topic
Blood Pressure and Hypertension Studies
Type
article
Field-Weighted Citation Impact
1.21

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Development of quality indicators for hypertension management at the primary health care level in South Africa

Stephen Campbell, Ntodeni Norah Ndwamato, Johanna C. Meyer, Enos M Rampamba et al.
3 citations
Journal of Human Hypertension
Blood Pressure and Hypertension Studies
1.21
article

Development of quality indicators for hypertension management at the primary health care level in South Africa

Stephen Campbell, Ntodeni Norah Ndwamato, Johanna C. Meyer, Enos M Rampamba, Brian Godman
article en
3 citations

Abstract

Despite many quality initiatives at the primary health care (PHC) level, little is known about the actual quality of care of patients diagnosed with hypertension in South Africa. This study aimed to develop quality indicators for hypertension management at the PHC level to improve the quality of care and patient outcomes. The RAND/UCLA Appropriateness Method, comprising two rounds, was used to develop clear, appropriate, and feasible evidence-based quality indicators for hypertension. In Round 1, a 9-point scale was used by a panel of 11 members to rate clarity and appropriateness of 102 hypertension quality indicator statements, grouped under 9 dimensions of quality hypertension management, using an online MS Excel® spreadsheet. In Round 2, 9 of the same panellists discussed all indicators and rated their appropriateness and feasibility during a remote online, interactive face-to-face MS Teams® meeting. Statements rated ≥7-9 with agreement were defined as either appropriate or feasible. The panel rated 46 hypertension quality indicator statements ≥7-9 with agreement for the appropriate and feasible measurement of the management of hypertension: monitoring (n = 16), review (n = 5), lifestyle advice (n = 9), tests (n = 7), intermediate outcomes (n = 6), referrals (n = 2) and practice/facility structures (n = 1). No indicator statements were rated both appropriate and feasible for measuring blood pressure levels and treatment. If applied, these indicators would improve monitoring and management of patients with hypertension, patient outcomes, and data quality in South Africa and result in more efficient use of scarce resources. This study can be replicable for improving care of other non-communicable diseases across Africa.

Journal of Human HypertensionVol. 39(2)
South African Medical Research Council (ZA), University of Strathclyde (GB), Manchester Academic Health Science Centre (GB), Sefako Makgatho Health Sciences University (ZA), University of Limpopo (ZA)
National Research Foundation, South African Agency for Science and Technology Advancement
Openalex Percentile: Top 18%
Blood Pressure and Hypertension Studies
1.21
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.