Design and analysis of a fast aperture LWIR continuous zoom optical system

This paper presents the design of a continuous zoom optical system operating in the long-wave infrared spectrum (8 - 12μm), compatible with an uncooled detector having a resolution of 640×480 pixels and a pixel size of 12μm. Focal length ranges from 20mm to 100mm, with corresponding aperture values varying from F/0.8 to F/1.1. In order to possess good optical performance and compactness, the optical system applied a number of diffractive and aspheric surfaces. This system consists of 5 elements with a total length of 180mm and is optimized at 8 focal positions. All configurations exhibit good optical quality, with RMS spot sizes smaller than the sensor pixel size and MTF values at Nyquist frequency close to the diffraction limit. Additionally, in order to give the system good imaging performance in the operating temperature range from -20°C to 60°C, an active mechanical compensation method was used.

Authors

Publication Details

Published
2024-10-14
DOI
https://doi.org/10.1117/12.3034517
Primary Topic
Photonic and Optical Devices
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Design and analysis of a fast aperture LWIR continuous zoom optical system

Dat Vu, Thanh Thao Nguyen, Dat Nguyen, Du Dang
Photonic and Optical Devices
article

Design and analysis of a fast aperture LWIR continuous zoom optical system

Dat Vu, Thanh Thao Nguyen, Dat Nguyen, Du Dang
article en

Abstract

This paper presents the design of a continuous zoom optical system operating in the long-wave infrared spectrum (8 - 12μm), compatible with an uncooled detector having a resolution of 640×480 pixels and a pixel size of 12μm. Focal length ranges from 20mm to 100mm, with corresponding aperture values varying from F/0.8 to F/1.1. In order to possess good optical performance and compactness, the optical system applied a number of diffractive and aspheric surfaces. This system consists of 5 elements with a total length of 180mm and is optimized at 8 focal positions. All configurations exhibit good optical quality, with RMS spot sizes smaller than the sensor pixel size and MTF values at Nyquist frequency close to the diffraction limit. Additionally, in order to give the system good imaging performance in the operating temperature range from -20°C to 60°C, an active mechanical compensation method was used.

Affordable and clean energy
Openalex Percentile: Top 84%
Photonic and Optical Devices
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.