An Experimental Investigation of Pressure Drop in Two-Phase Flow during the Condensation of R410A within Parallel Microchannels

In this study, the flow condensation of R-410A within 18 square microchannels arranged horizontally in parallel was experimentally investigated. All components of pressure drop, including expansion, contraction, deceleration, and friction, were quantified specifically for microchannels. The test conditions included saturation temperature, vapor quality, and mass flux, ranging from 18.86 to 24.22 bar, 0.09 to 0.92, and 200 to 445 kg/m2·s, respectively. The frictional pressure loss made up approximately 92.89% of the overall pressure reduction. The findings demonstrate that the pressure drop rises with higher mass flux and a lower saturation temperature. By comparing with correlations and semi-empirical models outlined in the literature across various scales, specimen types, and refrigerant media, correlations developed for two-phase adiabatic flows in multi-channel configurations can effectively predict the pressure drop in microchannel condensation processes. The model introduced by Sakamatapan and Wongwises demonstrated the highest predictive accuracy, with a mean absolute deviation of 8.4%.

Authors

Institutions

Publication Details

Journal
Energies
Published
2024-10-14
DOI
https://doi.org/10.3390/en17205105
Primary Topic
Heat Transfer and Boiling Studies
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

An Experimental Investigation of Pressure Drop in Two-Phase Flow during the Condensation of R410A within Parallel Microchannels

Luyao Guo, Long Huang, Zhi-jiang Jin, Jin-yuan Qian et al.
Energies
Heat Transfer and Boiling Studies
article

An Experimental Investigation of Pressure Drop in Two-Phase Flow during the Condensation of R410A within Parallel Microchannels

Luyao Guo, Long Huang, Zhi-jiang Jin, Jin-yuan Qian, Baoqing Liu
article en

Abstract

In this study, the flow condensation of R-410A within 18 square microchannels arranged horizontally in parallel was experimentally investigated. All components of pressure drop, including expansion, contraction, deceleration, and friction, were quantified specifically for microchannels. The test conditions included saturation temperature, vapor quality, and mass flux, ranging from 18.86 to 24.22 bar, 0.09 to 0.92, and 200 to 445 kg/m2·s, respectively. The frictional pressure loss made up approximately 92.89% of the overall pressure reduction. The findings demonstrate that the pressure drop rises with higher mass flux and a lower saturation temperature. By comparing with correlations and semi-empirical models outlined in the literature across various scales, specimen types, and refrigerant media, correlations developed for two-phase adiabatic flows in multi-channel configurations can effectively predict the pressure drop in microchannel condensation processes. The model introduced by Sakamatapan and Wongwises demonstrated the highest predictive accuracy, with a mean absolute deviation of 8.4%.

EnergiesVol. 17(20)
Wenzhou University (CN), Xi’an Jiaotong-Liverpool University (CN), Zhejiang University (CN)
State Key Laboratory of Air-conditioning Equipment and System Energy Conservation, National Natural Science Foundation of China, Zhejiang University
Affordable and clean energy
Openalex Percentile: Top 82%
Heat Transfer and Boiling Studies
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.