Critical Analysis of Bulk Current Injection (BCI) Testing Methods

In this paper, the two testing methods for bulk current injection (BCI) testing, the substitution and closed-loop method, are analyzed. It is critically questioned, if both methods can be seen as equivalent with regard to validation, test reproducibility and suitability for different types of equipment under test (EUT), when each method employ different location(s) of injection probes and different forward power application. For this analysis, a circuit model of the whole BCI setup for a frequency range from 1 MHz to 400 MHz was designed and verified by measurement, applying a constant current. Then, results of both methods are compared and it is assessed, if both methods can be seen as equivalent or one of the methods is more suitable for testing than the other.

Authors

Institutions

Publication Details

Published
2024-09-04
DOI
https://doi.org/10.1109/ae61743.2024.10710255
Citations
3
Primary Topic
Electrostatic Discharge in Electronics
Type
article
Field-Weighted Citation Impact
0.63
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Critical Analysis of Bulk Current Injection (BCI) Testing Methods

Martin Gabrišák, M. Bittera, Jozef Hallon
3 citations
Electrostatic Discharge in Electronics
0.63
article

Critical Analysis of Bulk Current Injection (BCI) Testing Methods

Martin Gabrišák, M. Bittera, Jozef Hallon
article en
3 citations

Abstract

In this paper, the two testing methods for bulk current injection (BCI) testing, the substitution and closed-loop method, are analyzed. It is critically questioned, if both methods can be seen as equivalent with regard to validation, test reproducibility and suitability for different types of equipment under test (EUT), when each method employ different location(s) of injection probes and different forward power application. For this analysis, a circuit model of the whole BCI setup for a frequency range from 1 MHz to 400 MHz was designed and verified by measurement, applying a constant current. Then, results of both methods are compared and it is assessed, if both methods can be seen as equivalent or one of the methods is more suitable for testing than the other.

Institute of Electrical Engineering of the Slovak Academy of Sciences (SK)
Openalex Percentile: Top 31%
Electrostatic Discharge in Electronics
0.63
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.