A Novel Third-Harmonic Voltage Protection Method for the Generator Stator Ground Fault of Nuclear Power Plant's Rotating Asynchronous Machine

The nuclear power plant's rotating asynchronous machine (RAM) is the sole power supply system of the control rod drive mechanism (CRDM). The current RAM's protection system consists of traditional discrete relays, which have low reliability and flexibility. The popularization of digital protection devices and new principles has been started in the engineering field. Based on the feature of the Zig-Zag star winding connection of the generator stator winding in RAM, this paper analyzes the after-ground fault third-harmonic voltage characteristics. It is found that when the fault resistance exceeds 5 kΩ, the application of the traditional third harmonic voltage criteria is difficult because of the low sensitivity. Thus, this paper proposes a novel protection method based on the variation in the third-harmonic voltage, effectively improving protection reliability by introducing restraining quantity. Simulation and dynamic model experiments show that, compared to the existing third-harmonic voltage criteria, the proposed method exhibits higher sensitivity and has an against fault resistance ability of at least 10 kΩ.

Authors

Institutions

Publication Details

Journal
IEEE Transactions on Power Delivery
Published
2024-10-14
DOI
https://doi.org/10.1109/tpwrd.2024.3479286
Citations
3
Primary Topic
High-Voltage Power Transmission Systems
Type
article
Field-Weighted Citation Impact
0.63

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

A Novel Third-Harmonic Voltage Protection Method for the Generator Stator Ground Fault of Nuclear Power Plant's Rotating Asynchronous Machine

Jian Qiao, Chenxiao Tang, Liming Tan, Yikai Wang et al.
3 citations
IEEE Transactions on Power Delivery
High-Voltage Power Transmission Systems
0.63
article

A Novel Third-Harmonic Voltage Protection Method for the Generator Stator Ground Fault of Nuclear Power Plant's Rotating Asynchronous Machine

Jian Qiao, Chenxiao Tang, Liming Tan, Yikai Wang, Xianggen Yin
article en
3 citations

Abstract

The nuclear power plant's rotating asynchronous machine (RAM) is the sole power supply system of the control rod drive mechanism (CRDM). The current RAM's protection system consists of traditional discrete relays, which have low reliability and flexibility. The popularization of digital protection devices and new principles has been started in the engineering field. Based on the feature of the Zig-Zag star winding connection of the generator stator winding in RAM, this paper analyzes the after-ground fault third-harmonic voltage characteristics. It is found that when the fault resistance exceeds 5 kΩ, the application of the traditional third harmonic voltage criteria is difficult because of the low sensitivity. Thus, this paper proposes a novel protection method based on the variation in the third-harmonic voltage, effectively improving protection reliability by introducing restraining quantity. Simulation and dynamic model experiments show that, compared to the existing third-harmonic voltage criteria, the proposed method exhibits higher sensitivity and has an against fault resistance ability of at least 10 kΩ.

IEEE Transactions on Power DeliveryVol. 39(6)
North China Electric Power University (CN), State Grid Hunan Electric Power Company Limited (CN), Huazhong University of Science and Technology (CN)
National Natural Science Foundation of China, Fundamental Research Funds for the Central Universities
Affordable and clean energy
Openalex Percentile: Top 31%
High-Voltage Power Transmission Systems
0.63
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

A Novel Third-Harmonic Voltage Protection Method for the Generator Stator Ground Fault of Nuclear Power Plant's Rotating Asynchronous Machine — Jian Qiao, Chenxiao Tang, et al. · IEEE Transactions on Power Delivery (2024) | TGRS Research Map | TGRS