Influence of Image Discretization and Patch Size on Microbubble Localization Precision

For ultrasound localization microscopy, the localization of microbubbles (MBs) is an essential part to obtain super-resolved maps of the vasculature. This article analyzes the impact of image discretization and patch size on the precision of different MB localization methods to reconcile different observations from previous studies, provide an estimate of feasible localization precision, and derive guidelines for an optimal parameter selection. For this purpose, the images of MBs were simulated with Gaussian point-spread functions (PSFs) of varying width parameter at randomly generated subpixel positions, and Rician distributed noise was added. Four localization methods were tested on the patches of different sizes (number of pixels ): Gaussian fit (GF), radial symmetry (RS) method, calculation of center of mass (CoM), and peak detection (PD). Additionally, the Cramér-Rao lower bound (CRLB) for the given estimation problem was calculated. Our results show that the localization precision is strongly influenced by the ratio of the PSF width parameter to the pixel size , as well as the patch size N. The best parameter combination depends on the localization method. Generally, very small ratios as well as large ratios in combination with small N lead to performance degradation. The GF as a representative of a model-based fit comes close to the CRLB and always performs best for the ratios given by image discretization if N is adapted to the PSF. To achieve good results with the GF and the RS method, a good rule of thumb is to set the pixel sizes and the patch sizes .

Authors

Institutions

Publication Details

Journal
IEEE Transactions on Ultrasonics Ferroelectrics and Frequency Control
Published
2024-10-14
DOI
https://doi.org/10.1109/tuffc.2024.3479710
Citations
2
Primary Topic
Fluid Dynamics and Mixing
Type
article
Field-Weighted Citation Impact
0.37

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Influence of Image Discretization and Patch Size on Microbubble Localization Precision

Georg Schmitz, Stefanie Dencks, Julia Sobolewski
2 citations
IEEE Transactions on Ultrasonics Ferroelectrics and Frequency Control
Fluid Dynamics and Mixing
0.37
article

Influence of Image Discretization and Patch Size on Microbubble Localization Precision

Georg Schmitz, Stefanie Dencks, Julia Sobolewski
article en
2 citations

Abstract

For ultrasound localization microscopy, the localization of microbubbles (MBs) is an essential part to obtain super-resolved maps of the vasculature. This article analyzes the impact of image discretization and patch size on the precision of different MB localization methods to reconcile different observations from previous studies, provide an estimate of feasible localization precision, and derive guidelines for an optimal parameter selection. For this purpose, the images of MBs were simulated with Gaussian point-spread functions (PSFs) of varying width parameter at randomly generated subpixel positions, and Rician distributed noise was added. Four localization methods were tested on the patches of different sizes (number of pixels ): Gaussian fit (GF), radial symmetry (RS) method, calculation of center of mass (CoM), and peak detection (PD). Additionally, the Cramér-Rao lower bound (CRLB) for the given estimation problem was calculated. Our results show that the localization precision is strongly influenced by the ratio of the PSF width parameter to the pixel size , as well as the patch size N. The best parameter combination depends on the localization method. Generally, very small ratios as well as large ratios in combination with small N lead to performance degradation. The GF as a representative of a model-based fit comes close to the CRLB and always performs best for the ratios given by image discretization if N is adapted to the PSF. To achieve good results with the GF and the RS method, a good rule of thumb is to set the pixel sizes and the patch sizes .

IEEE Transactions on Ultrasonics Ferroelectrics and Frequency ControlVol. 71(12: Breaking the Resolution)
Ruhr University Bochum (DE)
Deutsche Forschungsgemeinschaft
Openalex Percentile: Top 43%
Fluid Dynamics and Mixing
0.37
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Influence of Image Discretization and Patch Size on Microbubble Localization Precision — Georg Schmitz, Stefanie Dencks, et al. · IEEE Transactions on Ultrasonics Ferroelectrics and Frequency Control (2024) | TGRS Research Map | TGRS