Noncontact Blood Pressure Estimation From the Carotid Pulse Wave Signal Using a Modified ResNet-18 Network With LFMCW Radar

In this article, a radar-based noncontact blood pressure (BP) monitoring system has been proposed for systolic BP (SBP) and diastolic BP (DBP) estimation. A linear frequency-modulated continuous wave (LFMCW) radar sensor has been utilized to capture the carotid pulse wave signal contactlessly. After that, a modified residual neural network model based on the ResNet-18 architecture was constructed to estimate the BP values based on the radar-acquired carotid pulse wave signal. The experimental database with 100 human subjects has been collected in a laboratory environment. The record-wise mean absolute errors (MAEs) of SBP and DBP estimations are 3.51 and 2.44 mmHg, respectively. Regarding the standard deviation (STD), the error performance of SBP and DBP estimations are 6.90 and 4.61 mmHg, respectively. Furthermore, the subject-wise MAEs of SBP and DBP achieve 5.92 and 4.32 mmHg, respectively. The proposed method can be a good extension for cuffless BP measurement and potentially be applied in many scenarios that require dynamic BP tracking, such as sleep or perioperative periods.

Authors

Institutions

Publication Details

Journal
IEEE Sensors Journal
Published
2024-10-14
DOI
https://doi.org/10.1109/jsen.2024.3476130
Citations
7
Primary Topic
Non-Invasive Vital Sign Monitoring
Type
article
Field-Weighted Citation Impact
1.29

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Noncontact Blood Pressure Estimation From the Carotid Pulse Wave Signal Using a Modified ResNet-18 Network With LFMCW Radar

Zehan Wang, Biao Xue, Chuanwei Ding, Hong Hong et al.
7 citations
IEEE Sensors Journal
Non-Invasive Vital Sign Monitoring
1.29
article

Noncontact Blood Pressure Estimation From the Carotid Pulse Wave Signal Using a Modified ResNet-18 Network With LFMCW Radar

Zehan Wang, Biao Xue, Chuanwei Ding, Hong Hong, Heng Zhao, Xiaohua Zhu, Dongbo Xu, Zicheng Wang
article en
7 citations

Abstract

In this article, a radar-based noncontact blood pressure (BP) monitoring system has been proposed for systolic BP (SBP) and diastolic BP (DBP) estimation. A linear frequency-modulated continuous wave (LFMCW) radar sensor has been utilized to capture the carotid pulse wave signal contactlessly. After that, a modified residual neural network model based on the ResNet-18 architecture was constructed to estimate the BP values based on the radar-acquired carotid pulse wave signal. The experimental database with 100 human subjects has been collected in a laboratory environment. The record-wise mean absolute errors (MAEs) of SBP and DBP estimations are 3.51 and 2.44 mmHg, respectively. Regarding the standard deviation (STD), the error performance of SBP and DBP estimations are 6.90 and 4.61 mmHg, respectively. Furthermore, the subject-wise MAEs of SBP and DBP achieve 5.92 and 4.32 mmHg, respectively. The proposed method can be a good extension for cuffless BP measurement and potentially be applied in many scenarios that require dynamic BP tracking, such as sleep or perioperative periods.

IEEE Sensors JournalVol. 24(23)
Northwestern Polytechnical University (CN), Nanjing University of Science and Technology (CN)
National Natural Science Foundation of China, Natural Science Foundation of Jiangsu Province, Jiangsu Provincial Key Research and Development Program, Fundamental Research Funds for the Central Universities
Openalex Percentile: Top 21%
Non-Invasive Vital Sign Monitoring
1.29
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.