Power handling in a highly-radiative negative triangularity pilot plant

Abstract This work explores detailed power handling solutions for a class of high-field, highly-radiative negative triangularity (NT) reactors based around the MANTA concept (Rutherford et al 2024 Plasma Phys. Control. Fusion ). The divertor design is kept as simple as possible, opting for a standard divertor with standard leg length. FreeGS is used to create an equilibrium for the boundary region, prioritizing a short outer leg length of only ∼50 cm (∼40% of the minor radius). The UEDGE code package is used for the boundary plasma solution to track plasma temperatures and fluxes to the divertor targets. It is found that for <mml:math xmlns:mml="http://www.w3.org/1998/Math/MathML" overflow="scroll"> <mml:mrow> <mml:msub> <mml:mi>P</mml:mi> <mml:mrow> <mml:mi>SOL</mml:mi> </mml:mrow> </mml:msub> </mml:mrow> </mml:math> = 25 MW and <mml:math xmlns:mml="http://www.w3.org/1998/Math/MathML" overflow="scroll"> <mml:mrow> <mml:msub> <mml:mi>n</mml:mi> <mml:mrow> <mml:mi>sep</mml:mi> </mml:mrow> </mml:msub> <mml:mo>=</mml:mo> <mml:mn>0.96</mml:mn> <mml:mo>×</mml:mo> <mml:msup> <mml:mn>10</mml:mn> <mml:mrow> <mml:mn>20</mml:mn> </mml:mrow> </mml:msup> </mml:mrow> </mml:math> m −3 , conditions consistent with initial core transport modeling, little additional power mitigation is necessary. For a fixed impurity fraction of just 0.13% Ne in the plasma, the peak heat flux density at the more heavily loaded outer targets falls to 7.8 MW m −2 , while the electron temperature <mml:math xmlns:mml="http://www.w3.org/1998/Math/MathML" overflow="scroll"> <mml:mrow> <mml:msub> <mml:mi>T</mml:mi> <mml:mrow> <mml:mi mathvariant="normal">e</mml:mi> </mml:mrow> </mml:msub> </mml:mrow> </mml:math> remains just under 5 eV. Scans around the parameter space reveal that even at densities lower than in the primary operating scenario, <mml:math xmlns:mml="http://www.w3.org/1998/Math/MathML" overflow="scroll"> <mml:mrow> <mml:msub> <mml:mi>P</mml:mi> <mml:mrow> <mml:mi>SOL</mml:mi> </mml:mrow> </mml:msub> </mml:mrow> </mml:math> can be increased up to 50 MW, so long as a slightly higher fraction of extrinsic radiator is used. With less than 1% neon (Ne) impurity content, the divertor still experiences less than 10 MW m −2 at the outer target. Design of the plasma-facing components includes a close-fitting vacuum vessel with a tungsten inner surface as well as FLiBe-carrying cooling channels fashioned into the VV wall directly behind the divertor targets. For the seeded heat flux profile, Ansys Fluent heat transfer simulations estimate that the outer target temperature remains at just below 1550 ∘ C. Initial scoping of advanced divertor designs shows that for an X-divertor, detachment of the outer target becomes much simpler, and plasma fluxes to the targets drop considerably with only 0.01% Ne content.

Authors

Institutions

Publication Details

Journal
Plasma Physics and Controlled Fusion
Published
2024-10-14
DOI
https://doi.org/10.1088/1361-6587/ad867a
Citations
4
Primary Topic
Magnetic confinement fusion research
Type
article
Field-Weighted Citation Impact
2.64

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Power handling in a highly-radiative negative triangularity pilot plant

David P. Arnold, M.A. Miller, A. Nelson, G. Rutherford et al.
4 citations
Plasma Physics and Controlled Fusion
Magnetic confinement fusion research
2.64
article

Power handling in a highly-radiative negative triangularity pilot plant

David P. Arnold, M.A. Miller, A. Nelson, G. Rutherford, C. Paz-Soldan, M. Wigram, D.G. Whyte, J. Witham, Charles W. Cummings, H. Choudhury
article en
4 citations

Abstract

Abstract This work explores detailed power handling solutions for a class of high-field, highly-radiative negative triangularity (NT) reactors based around the MANTA concept (Rutherford et al 2024 Plasma Phys. Control. Fusion ). The divertor design is kept as simple as possible, opting for a standard divertor with standard leg length. FreeGS is used to create an equilibrium for the boundary region, prioritizing a short outer leg length of only ∼50 cm (∼40% of the minor radius). The UEDGE code package is used for the boundary plasma solution to track plasma temperatures and fluxes to the divertor targets. It is found that for <mml:math xmlns:mml="http://www.w3.org/1998/Math/MathML" overflow="scroll"> <mml:mrow> <mml:msub> <mml:mi>P</mml:mi> <mml:mrow> <mml:mi>SOL</mml:mi> </mml:mrow> </mml:msub> </mml:mrow> </mml:math> = 25 MW and <mml:math xmlns:mml="http://www.w3.org/1998/Math/MathML" overflow="scroll"> <mml:mrow> <mml:msub> <mml:mi>n</mml:mi> <mml:mrow> <mml:mi>sep</mml:mi> </mml:mrow> </mml:msub> <mml:mo>=</mml:mo> <mml:mn>0.96</mml:mn> <mml:mo>×</mml:mo> <mml:msup> <mml:mn>10</mml:mn> <mml:mrow> <mml:mn>20</mml:mn> </mml:mrow> </mml:msup> </mml:mrow> </mml:math> m −3 , conditions consistent with initial core transport modeling, little additional power mitigation is necessary. For a fixed impurity fraction of just 0.13% Ne in the plasma, the peak heat flux density at the more heavily loaded outer targets falls to 7.8 MW m −2 , while the electron temperature <mml:math xmlns:mml="http://www.w3.org/1998/Math/MathML" overflow="scroll"> <mml:mrow> <mml:msub> <mml:mi>T</mml:mi> <mml:mrow> <mml:mi mathvariant="normal">e</mml:mi> </mml:mrow> </mml:msub> </mml:mrow> </mml:math> remains just under 5 eV. Scans around the parameter space reveal that even at densities lower than in the primary operating scenario, <mml:math xmlns:mml="http://www.w3.org/1998/Math/MathML" overflow="scroll"> <mml:mrow> <mml:msub> <mml:mi>P</mml:mi> <mml:mrow> <mml:mi>SOL</mml:mi> </mml:mrow> </mml:msub> </mml:mrow> </mml:math> can be increased up to 50 MW, so long as a slightly higher fraction of extrinsic radiator is used. With less than 1% neon (Ne) impurity content, the divertor still experiences less than 10 MW m −2 at the outer target. Design of the plasma-facing components includes a close-fitting vacuum vessel with a tungsten inner surface as well as FLiBe-carrying cooling channels fashioned into the VV wall directly behind the divertor targets. For the seeded heat flux profile, Ansys Fluent heat transfer simulations estimate that the outer target temperature remains at just below 1550 ∘ C. Initial scoping of advanced divertor designs shows that for an X-divertor, detachment of the outer target becomes much simpler, and plasma fluxes to the targets drop considerably with only 0.01% Ne content.

Plasma Physics and Controlled FusionVol. 66(12)
Fusion (United States) (US), Plasma Technology (United States) (US), Fusion Academy (US), Massachusetts Institute of Technology (US), Columbia University (US)
Fusion Energy Sciences
Affordable and clean energy
Openalex Percentile: Top 7%
Magnetic confinement fusion research
2.64
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.