The Virgo Newtonian calibration system for the O4 observing run

Abstract After initial tests performed during previous observing runs, a Newtonian calibrator (NCal) system was developed and installed on the Virgo gravitational wave detector for the O4 observing run. This system, which is continuously operated, provides the absolute calibration of Virgo for this run. Its <mml:math xmlns:mml="http://www.w3.org/1998/Math/MathML" overflow="scroll"> <mml:mrow> <mml:mn>1</mml:mn> <mml:mstyle displaystyle="false" scriptlevel="0"> <mml:mtext>-</mml:mtext> </mml:mstyle> <mml:mi>σ</mml:mi> </mml:mrow> </mml:math> uncertainty of 0.17% on the amplitudes of the injected signals is better than that obtained with other calibration techniques like the photon calibrator (PCal). This paper presents this NCal system and details the different sources of uncertainties.

Authors

Institutions

Publication Details

Journal
Classical and Quantum Gravity
Published
2024-10-14
DOI
https://doi.org/10.1088/1361-6382/ad869c
Citations
1
Primary Topic
Pulsars and Gravitational Waves Research
Type
article
Field-Weighted Citation Impact
0.33

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

The Virgo Newtonian calibration system for the O4 observing run

E. Dangelser, P. Van Hove, F. Aubin, A Syx et al.
1 citations
Classical and Quantum Gravity
Pulsars and Gravitational Waves Research
0.33
article

The Virgo Newtonian calibration system for the O4 observing run

E. Dangelser, P. Van Hove, F. Aubin, A Syx, T. Pradier, B. Mours, D. Estevez, A. Masserot
article en
1 citations

Abstract

Abstract After initial tests performed during previous observing runs, a Newtonian calibrator (NCal) system was developed and installed on the Virgo gravitational wave detector for the O4 observing run. This system, which is continuously operated, provides the absolute calibration of Virgo for this run. Its <mml:math xmlns:mml="http://www.w3.org/1998/Math/MathML" overflow="scroll"> <mml:mrow> <mml:mn>1</mml:mn> <mml:mstyle displaystyle="false" scriptlevel="0"> <mml:mtext>-</mml:mtext> </mml:mstyle> <mml:mi>σ</mml:mi> </mml:mrow> </mml:math> uncertainty of 0.17% on the amplitudes of the injected signals is better than that obtained with other calibration techniques like the photon calibrator (PCal). This paper presents this NCal system and details the different sources of uncertainties.

Classical and Quantum GravityVol. 41(23)
Laboratoire d’Annecy de Physique des Particules (FR), Institut Pluridisciplinaire Hubert Curien (FR)
Agence Nationale de la Recherche
Openalex Percentile: Top 34%
Pulsars and Gravitational Waves Research
0.33
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.