Frequency noise suppression of the high-power pumping laser in the SERF atomic magnetometer

Abstract A high-sensitivity spin exchange relaxation free (SERF) atomic magnetometer based on a noise-suppressed master oscillator power amplifier (MOPA) system is demonstrated. The spectrum and frequency noise of the laser are measured and it is proved that the frequency noise in the MOPA system is affected by the amplified spontaneous emission (ASE) stimulated from the power amplifier. The frequency noise of the MOPA system is decreased by filtering out the ASE background in the spectrum through a bandpass filter. The sensitivity of the SERF atomic magnetometer is improved by using the frequency noise-suppressed MOPA system as a pumping laser. This method can also be applied to other precision measurement fields based on MOPA systems that have high requirements for frequency noise of lasers.

Authors

Institutions

Publication Details

Journal
Measurement Science and Technology
Published
2024-10-14
DOI
https://doi.org/10.1088/1361-6501/ad8670
Citations
1
Primary Topic
Atomic and Subatomic Physics Research
Type
article
Field-Weighted Citation Impact
0.34

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Frequency noise suppression of the high-power pumping laser in the SERF atomic magnetometer

Zengliang Hu, Lihong Duan, Ning Ma, Qingbo Liu et al.
1 citations
Measurement Science and Technology
Atomic and Subatomic Physics Research
0.34
article

Frequency noise suppression of the high-power pumping laser in the SERF atomic magnetometer

Zengliang Hu, Lihong Duan, Ning Ma, Qingbo Liu, Guiqi Wang
article en
1 citations

Abstract

Abstract A high-sensitivity spin exchange relaxation free (SERF) atomic magnetometer based on a noise-suppressed master oscillator power amplifier (MOPA) system is demonstrated. The spectrum and frequency noise of the laser are measured and it is proved that the frequency noise in the MOPA system is affected by the amplified spontaneous emission (ASE) stimulated from the power amplifier. The frequency noise of the MOPA system is decreased by filtering out the ASE background in the spectrum through a bandpass filter. The sensitivity of the SERF atomic magnetometer is improved by using the frequency noise-suppressed MOPA system as a pumping laser. This method can also be applied to other precision measurement fields based on MOPA systems that have high requirements for frequency noise of lasers.

Measurement Science and TechnologyVol. 36(1)
Hefei University (CN), Extreme Light Infrastructure - Nuclear Physics (RO), Beihang University (CN)
National Natural Science Foundation of China
Openalex Percentile: Top 40%
Atomic and Subatomic Physics Research
0.34
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Frequency noise suppression of the high-power pumping laser in the SERF atomic magnetometer — Zengliang Hu, Lihong Duan, et al. · Measurement Science and Technology (2024) | TGRS Research Map | TGRS