Hemodynamic Support With the Impella 5.5 Acute Mechanical Circulatory Support Device

The Impella 5.5 is increasingly used as a bridge to recovery or heart replacement therapies despite lack of clinical trial evidence. We report real-world outcomes and hemodynamic effects of 150 consecutive patients from a single, high-volume center. Primary outcome was incidence of recovery, durable left ventricular assist device (LVAD), or heart transplant compared with incidence of death at 90 days. Secondary outcomes included hemodynamic trends and upgrade to veno-arterial extracorporeal membrane oxygenation (VA-ECMO) support. The composite endpoint occurred in 59.3% and death in 18.8% of patients (incidence rate ratio: 8.1 [95% confidence interval {CI}: 5.4-12.2], p < 0.001). Decreases in pulmonary artery diastolic pressure (PADP) ( p = 0.026), estimated pulmonary effective arterial elastance (Ea) ( p < 0.001), and vasoactive-inotropic score (VIS) ( p < 0.001) occurred during Impella 5.5 support. Pulmonary artery diastolic pressure correlated with estimated Ea ( p < 0.001), suggesting improved right ventricle (RV) afterload with left ventricle (LV) unloading. Veno-arterial extracorporeal membrane oxygenation upgrade occurred in 11.3% of patients who had higher baseline right atrial pressure (RAP) (16.0 [9.0-20.5] vs. 9.0 [7.0-12.0], p = 0.022), PADP (28.5 [25.0-31.0] vs. 23.0 [18.0-28.0], p = 0.011), and lower pulmonary artery pulsatility index (PAPi) (1.45 [0.82-3.45] vs. 2.5 [1.65-3.86], p = 0.029). Upgrade patients had higher repeated measures trends in RAP ( p < 0.001) and PADP ( p = 0.015). The Impella 5.5 improved hemodynamics and effectively bridged to recovery or heart replacement therapies. Co-existing RV dysfunction can be supported on Impella 5.5 with careful hemodynamic trend monitoring.

Authors

Institutions

Publication Details

Journal
ASAIO Journal
Published
2024-10-14
DOI
https://doi.org/10.1097/mat.0000000000002331
Citations
2
Primary Topic
Mechanical Circulatory Support Devices
Type
article
Field-Weighted Citation Impact
0.37
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Hemodynamic Support With the Impella 5.5 Acute Mechanical Circulatory Support Device

Matthew S. Delfiner, Aditya G. Parikh, Joyce Wanglee Wald, James W. Schurr et al.
2 citations
ASAIO Journal
Mechanical Circulatory Support Devices
0.37
article

Hemodynamic Support With the Impella 5.5 Acute Mechanical Circulatory Support Device

Matthew S. Delfiner, Aditya G. Parikh, Joyce Wanglee Wald, James W. Schurr, Yoav Karpenshif, Juan Ortega–Legaspi, Marisa Cevasco, Alyson N. Brown, Mary Frances Quinn, Adrian Pearson
article en
2 citations

Abstract

The Impella 5.5 is increasingly used as a bridge to recovery or heart replacement therapies despite lack of clinical trial evidence. We report real-world outcomes and hemodynamic effects of 150 consecutive patients from a single, high-volume center. Primary outcome was incidence of recovery, durable left ventricular assist device (LVAD), or heart transplant compared with incidence of death at 90 days. Secondary outcomes included hemodynamic trends and upgrade to veno-arterial extracorporeal membrane oxygenation (VA-ECMO) support. The composite endpoint occurred in 59.3% and death in 18.8% of patients (incidence rate ratio: 8.1 [95% confidence interval {CI}: 5.4-12.2], p < 0.001). Decreases in pulmonary artery diastolic pressure (PADP) ( p = 0.026), estimated pulmonary effective arterial elastance (Ea) ( p < 0.001), and vasoactive-inotropic score (VIS) ( p < 0.001) occurred during Impella 5.5 support. Pulmonary artery diastolic pressure correlated with estimated Ea ( p < 0.001), suggesting improved right ventricle (RV) afterload with left ventricle (LV) unloading. Veno-arterial extracorporeal membrane oxygenation upgrade occurred in 11.3% of patients who had higher baseline right atrial pressure (RAP) (16.0 [9.0-20.5] vs. 9.0 [7.0-12.0], p = 0.022), PADP (28.5 [25.0-31.0] vs. 23.0 [18.0-28.0], p = 0.011), and lower pulmonary artery pulsatility index (PAPi) (1.45 [0.82-3.45] vs. 2.5 [1.65-3.86], p = 0.029). Upgrade patients had higher repeated measures trends in RAP ( p < 0.001) and PADP ( p = 0.015). The Impella 5.5 improved hemodynamics and effectively bridged to recovery or heart replacement therapies. Co-existing RV dysfunction can be supported on Impella 5.5 with careful hemodynamic trend monitoring.

ASAIO JournalVol. 71(4)
Hospital of the University of Pennsylvania (US), University of Pennsylvania (US)
Good health and well-being
Openalex Percentile: Top 43%
Mechanical Circulatory Support Devices
0.37
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.