Wire-in-needle versus conventional syringe-on-needle technique for ultrasound-guided central venous catheter insertion in the internal jugular vein: the WIN randomized trial
The wire-in-needle technique-compared with the syringe-on-needle technique-did not reduce the time to successful guidewire insertion in the internal jugular vein. Clinicians can consider either technique for ultrasound-guided CVC insertion in adults.
Authors
- Leonie Schulte‐Uentrop
- Moritz Flick (ORCID: https://orcid.org/0000-0003-4415-9956)
- Bernd Saugel (ORCID: https://orcid.org/0000-0001-6619-0722)
- Daniel I. Sessler (ORCID: https://orcid.org/0000-0001-9932-3077)
- Frederick M. Koster
- Kristen K Thomsen (ORCID: https://orcid.org/0000-0001-9187-9724)
- Karim Kouz (ORCID: https://orcid.org/0000-0001-8107-6952)
- Jovana Stekovic
- Alina Bergholz (ORCID: https://orcid.org/0000-0001-8240-3812)
- Christian Zöllner
Institutions
- Universität Hamburg (DE)
- Outcomes Research Consortium (US)
- University Medical Center Hamburg-Eppendorf (DE)
- The University of Texas Health Science Center (US)
Publication Details
- Journal
- Journal of Clinical Monitoring and Computing
- Published
- 2024-10-14
- DOI
- https://doi.org/10.1007/s10877-024-01232-4
- Citations
- 1
- Primary Topic
- Central Venous Catheters and Hemodialysis
- Type
- article
- Field-Weighted Citation Impact
- 0.74