Deep Learning–Based Estimation of Radiographic Position to Automatically Set Up the X-Ray Prime Factors
Radiation dose and image quality in radiology are influenced by the X-ray prime factors: KVp, mAs, and source-detector distance. These parameters are set by the X-ray technician prior to the acquisition considering the radiographic position. A wrong setting of these parameters may result in exposure errors, forcing the test to be repeated with the increase of the radiation dose delivered to the patient. This work presents a novel approach based on deep learning that automatically estimates the radiographic position from a photograph captured prior to X-ray exposure, which can then be used to select the optimal prime factors. We created a database using 66 radiographic positions commonly used in clinical settings, prospectively obtained during 2022 from 75 volunteers in two different X-ray facilities. The architecture for radiographic position classification was a lightweight version of ConvNeXt trained with fine-tuning, discriminative learning rates, and a one-cycle policy scheduler. Our resulting model achieved an accuracy of 93.17% for radiographic position classification and increased to 95.58% when considering the correct selection of prime factors, since half of the errors involved positions with the same KVp and mAs values. Most errors occurred for radiographic positions with similar patient pose in the photograph. Results suggest the feasibility of the method to facilitate the acquisition workflow reducing the occurrence of exposure errors while preventing unnecessary radiation dose delivered to patients.
Authors
- Mónica Abella (ORCID: https://orcid.org/0000-0002-4847-7233)
- Manuel Desco (ORCID: https://orcid.org/0000-0003-0989-3231)
- Rollin Gimenez (ORCID: https://orcid.org/0000-0002-3090-126X)
- Carlos F. Del Cerro (ORCID: https://orcid.org/0000-0002-0112-9709)
- James M. Ortega (ORCID: https://orcid.org/0009-0001-0170-5120)
- Javier Garcia‐Blas (ORCID: https://orcid.org/0000-0003-1452-1918)
- K. Sosenko
Institutions
- Instituto de Salud Carlos III (ES)
- Hospital General Universitario Gregorio Marañón (ES)
- Centro de Investigación Biomédica en Red de Salud Mental (ES)
- Centro Nacional de Epidemiología (ES)
- Spanish National Centre for Cardiovascular Research (ES)
- Universidad Carlos III de Madrid (ES)
Publication Details
- Journal
- Journal of Imaging Informatics in Medicine
- Published
- 2024-10-14
- DOI
- https://doi.org/10.1007/s10278-024-01256-x
- Citations
- 2
- Primary Topic
- Radiomics and Machine Learning in Medical Imaging
- Type
- article
- Field-Weighted Citation Impact
- 0.81
Funders
- European Commission
- Ministerio de Ciencia e Innovación
- Centro Nacional de Investigaciones Cardiovasculares
- Instituto de Salud Carlos III
- Horizon 2020
- European Regional Development Fund
- Agencia Estatal de Investigación