Free radical detection in precision-cut mouse liver slices with diamond-based quantum sensing

Free radical generation plays a key role in many biological processes including cell communication, maturation, and aging. In addition, free radical generation is usually elevated in cells under stress as is the case for many different pathological conditions. In liver tissue, cells produce radicals when exposed to toxic substances but also, for instance, in cancer, alcoholic liver disease and liver cirrhosis. However, free radicals are small, short-lived, and occur in low abundance making them challenging to detect and especially to time resolve, leading to a lack of nanoscale information. Recently, our group has demonstrated that diamond-based quantum sensing offers a solution to measure free radical generation in single living cells. The method is based on defects in diamonds, the so-called nitrogen-vacancy centers, which change their optical properties based on their magnetic surrounding. As a result, this technique reveals magnetic resonance signals by optical means offering high sensitivity. However, compared to cells, there are several challenges that we resolved here: Tissues are more fragile, have a higher background fluorescence, have less particle uptake, and do not adhere to microscopy slides. Here, we overcame those challenges and adapted the method to perform measurements in living tissues. More specifically, we used precision-cut liver slices and were able to detect free radical generation during a stress response to ethanol, as well as the reduction in the radical load after adding an antioxidant.

Authors

Institutions

Publication Details

Journal
Proceedings of the National Academy of Sciences
Published
2024-10-14
DOI
https://doi.org/10.1073/pnas.2317921121
Citations
8
Primary Topic
Diamond and Carbon-based Materials Research
Type
article
Field-Weighted Citation Impact
0.94

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Free radical detection in precision-cut mouse liver slices with diamond-based quantum sensing

Arturo Elías-Llumbet, Peter Olinga, Geert van den Bogaart, Dorenda Oosterhuis et al.
8 citations
Proceedings of the National Academy of Sciences
Diamond and Carbon-based Materials Research
0.94
article

Free radical detection in precision-cut mouse liver slices with diamond-based quantum sensing

Arturo Elías-Llumbet, Peter Olinga, Geert van den Bogaart, Dorenda Oosterhuis, Claudia Reyes-San-Martin, Romana Schirhagl, Elkin Escobar-Chaves, Willem Woudstra, Britt Coenen, Rinse de Boer, Felipe Perona Martínez, Alina Sigaeva, Robin Kisabacak, Yue Zhang, Siyu Fan, Alan Gorter
article en
8 citations

Abstract

Free radical generation plays a key role in many biological processes including cell communication, maturation, and aging. In addition, free radical generation is usually elevated in cells under stress as is the case for many different pathological conditions. In liver tissue, cells produce radicals when exposed to toxic substances but also, for instance, in cancer, alcoholic liver disease and liver cirrhosis. However, free radicals are small, short-lived, and occur in low abundance making them challenging to detect and especially to time resolve, leading to a lack of nanoscale information. Recently, our group has demonstrated that diamond-based quantum sensing offers a solution to measure free radical generation in single living cells. The method is based on defects in diamonds, the so-called nitrogen-vacancy centers, which change their optical properties based on their magnetic surrounding. As a result, this technique reveals magnetic resonance signals by optical means offering high sensitivity. However, compared to cells, there are several challenges that we resolved here: Tissues are more fragile, have a higher background fluorescence, have less particle uptake, and do not adhere to microscopy slides. Here, we overcame those challenges and adapted the method to perform measurements in living tissues. More specifically, we used precision-cut liver slices and were able to detect free radical generation during a stress response to ethanol, as well as the reduction in the radical load after adding an antioxidant.

Proceedings of the National Academy of SciencesVol. 121(43)
University Medical Center Groningen (NL), University of Groningen (NL), Universidad de Antioquia (CO), University of Chile (CL)
Chinese Government Scholarship
Good health and well-being
Openalex Percentile: Top 23%
Diamond and Carbon-based Materials Research
0.94
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.