Research on Control of Pump and Valve Testing Equipment
Abstract The complex flow state of the fluid makes it difficult for the pump valve to accurately control it. A study was conducted on the pressure flow control of a valve control device for gas-liquid two-phase flow, and experiments were conducted on the joint control of gas-liquid two-phase flow. The results showed that pressure has a significant impact on control, and it is necessary to ensure that pressure remains constant during the control process. The joint control of gas-liquid two-phase flow has consistency in changes, and precise control of gas-liquid two-phase flow can be achieved through studying consistency.
Authors
- LI Xue-jing
Institutions
- Shanghai Institute of Measurement and Testing Technology (CN)
Publication Details
- Journal
- Journal of Physics Conference Series
- Published
- 2024-10-01
- DOI
- https://doi.org/10.1088/1742-6596/2860/1/012012
- Primary Topic
- Hydraulic and Pneumatic Systems
- Type
- article
- Field-Weighted Citation Impact
- 0.00