Dilation framing camera with the dual-pulse excitation technique

In an inertial confinement fusion (ICF) ultrafast diagnostic system that is based on electron beam time-dilation, an ultrafast electrical pulse is used to excite a microstrip photocathode (PC), which generates a varying PC voltage to obtain a photoelectron velocity that varies with emission time. The photoelectron beam achieves time-dilation through the drift process and is then detected by a time-resolved sensor, thereby increasing the temporal resolution of the diagnostic system. A pulse time-dilation diagnostic system is simulated, while the sensor is a gated microchannel plate (MCP) detector with a temporal resolution of 100 ps and an excitation pulse on a PC with a slope of 3 V/ps; the diagnostic system achieves a temporal resolution of 11.12 ps. However, the excitation pulse creates a voltage difference across the PC. A voltage difference of 900 V can be acquired for a PC length of 60 mm, which yields a nonuniform spatial resolution ranging from 30.4 µm to approximately 3000 µm. Furthermore, the voltage difference across the PC also limits the frame size to 2.2 mm along the pulse propagation direction according to the simulation results. To achieve a uniform spatial resolution and a larger frame size, a dual-pulse excitation technique on a PC is presented, which is the technique to symmetrically apply voltage pulses at both ends of the PC microstrip. The theoretical results show that this technique will improve the uniformity of the PC voltage spatial distribution. When the PC pulse slope is 3 V/ps and the dual-pulse excitation technique is employed, the diagnostic system has a temporal resolution of 5.91 ps and a uniform spatial resolution of 30.4 µm. Furthermore, the frame size along the pulse propagation direction is improved to the effective length of the microstrip PC.

Authors

Publication Details

Journal
Applied Optics
Published
2024-10-14
DOI
https://doi.org/10.1364/ao.538950
Primary Topic
Optical measurement and interference techniques
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Dilation framing camera with the dual-pulse excitation technique

Lijuan Xiang, Houzhi Cai, Youlin Ma, Qiu-Yan Luo et al.
Applied Optics
Optical measurement and interference techniques
article

Dilation framing camera with the dual-pulse excitation technique

Lijuan Xiang, Houzhi Cai, Youlin Ma, Qiu-Yan Luo, Jinyuan Liu, Zhuoming Du
article en

Abstract

In an inertial confinement fusion (ICF) ultrafast diagnostic system that is based on electron beam time-dilation, an ultrafast electrical pulse is used to excite a microstrip photocathode (PC), which generates a varying PC voltage to obtain a photoelectron velocity that varies with emission time. The photoelectron beam achieves time-dilation through the drift process and is then detected by a time-resolved sensor, thereby increasing the temporal resolution of the diagnostic system. A pulse time-dilation diagnostic system is simulated, while the sensor is a gated microchannel plate (MCP) detector with a temporal resolution of 100 ps and an excitation pulse on a PC with a slope of 3 V/ps; the diagnostic system achieves a temporal resolution of 11.12 ps. However, the excitation pulse creates a voltage difference across the PC. A voltage difference of 900 V can be acquired for a PC length of 60 mm, which yields a nonuniform spatial resolution ranging from 30.4 µm to approximately 3000 µm. Furthermore, the voltage difference across the PC also limits the frame size to 2.2 mm along the pulse propagation direction according to the simulation results. To achieve a uniform spatial resolution and a larger frame size, a dual-pulse excitation technique on a PC is presented, which is the technique to symmetrically apply voltage pulses at both ends of the PC microstrip. The theoretical results show that this technique will improve the uniformity of the PC voltage spatial distribution. When the PC pulse slope is 3 V/ps and the dual-pulse excitation technique is employed, the diagnostic system has a temporal resolution of 5.91 ps and a uniform spatial resolution of 30.4 µm. Furthermore, the frame size along the pulse propagation direction is improved to the effective length of the microstrip PC.

Applied OpticsVol. 63(31)
National Natural Science Foundation of China, Basic and Applied Basic Research Foundation of Guangdong Province
Affordable and clean energy
Openalex Percentile: Top 83%
Optical measurement and interference techniques
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.