Analytical solution of a microrobot-blood vessel interaction model

This study develops a dynamics model of a microrobot vibrating in a blood vessel aiming to detect potential cancer metastasis. We derive an analytical solution for microrobot's motion, considering interactions with the vessel walls modelled by a linear spring-dashpot and a constant damping value for blood viscosity. The model facilitates instantaneous state transitions of the microrobot, such as contact with the vessel wall and free motion within the fluid. Amplitudes and phase angles from the transient solutions of dynamics model of the microrobot are solved at arbitrary moments, providing insights into its transient dynamics. The analytical solution of the proposed system is validated by experimental data, serving as a benchmark to examine the influence of pertinent parameters on microrobot's dynamic response. It is found that the contact force transmitted to the vessel wall, assessed by system's transmissibility function dependent on damping and frequency ratios, decreases with increasing damping ratio and intensifies when the frequency ratio is below <mml:math xmlns:mml="http://www.w3.org/1998/Math/MathML"><mml:msqrt><mml:mn>2</mml:mn></mml:msqrt> </mml:math> . At the frequency ratio is equal to 1, resonance phenomenon is dominated by the magnification factor linked to the damping ratio, increasing the amplitude of resonance as damping decreases. Finally, different sets of system parameters, including excitation frequency and magnitude, fluid damping, vessel wall's stiffness and damping, reveal multi-periodic motions and fake collision of the microrobot with the vessel wall. Simulation results imply that these phenomena are minimally affected by vessel wall's stiffness but are significantly influenced by other parameters, such as fluid damping coefficient and damping coefficient of the blood vessel wall. This research provides a robust theoretical foundation for developing control strategies for microrobots aimed at detecting cancer metastasis.

Authors

Institutions

Publication Details

Journal
Nonlinear Dynamics
Published
2024-10-14
DOI
https://doi.org/10.1007/s11071-024-10318-2
Citations
7
Primary Topic
Micro and Nano Robotics
Type
article
Field-Weighted Citation Impact
2.18

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Analytical solution of a microrobot-blood vessel interaction model

Antoine Ferreira, Andrew Bickerdike, Gengxiang Wang, Yang Liu
7 citations
Nonlinear Dynamics
Micro and Nano Robotics
2.18
article

Analytical solution of a microrobot-blood vessel interaction model

Antoine Ferreira, Andrew Bickerdike, Gengxiang Wang, Yang Liu
article en
7 citations

Abstract

This study develops a dynamics model of a microrobot vibrating in a blood vessel aiming to detect potential cancer metastasis. We derive an analytical solution for microrobot's motion, considering interactions with the vessel walls modelled by a linear spring-dashpot and a constant damping value for blood viscosity. The model facilitates instantaneous state transitions of the microrobot, such as contact with the vessel wall and free motion within the fluid. Amplitudes and phase angles from the transient solutions of dynamics model of the microrobot are solved at arbitrary moments, providing insights into its transient dynamics. The analytical solution of the proposed system is validated by experimental data, serving as a benchmark to examine the influence of pertinent parameters on microrobot's dynamic response. It is found that the contact force transmitted to the vessel wall, assessed by system's transmissibility function dependent on damping and frequency ratios, decreases with increasing damping ratio and intensifies when the frequency ratio is below <mml:math xmlns:mml="http://www.w3.org/1998/Math/MathML"><mml:msqrt><mml:mn>2</mml:mn></mml:msqrt> </mml:math> . At the frequency ratio is equal to 1, resonance phenomenon is dominated by the magnification factor linked to the damping ratio, increasing the amplitude of resonance as damping decreases. Finally, different sets of system parameters, including excitation frequency and magnitude, fluid damping, vessel wall's stiffness and damping, reveal multi-periodic motions and fake collision of the microrobot with the vessel wall. Simulation results imply that these phenomena are minimally affected by vessel wall's stiffness but are significantly influenced by other parameters, such as fluid damping coefficient and damping coefficient of the blood vessel wall. This research provides a robust theoretical foundation for developing control strategies for microrobots aimed at detecting cancer metastasis.

Nonlinear DynamicsVol. 113(3)
Xi'an University of Architecture and Technology (CN), University of Exeter (GB), Laboratoire Pluridisciplinaire de Recherche en Ingénierie des Systèmes, Mécanique et Energétique (FR), Services déconcentrés d'appui à la recherche Val de Loire (FR), Institut National des Sciences Appliquées Centre Val de Loire (FR)
UK Research and Innovation, National Natural Science Foundation of China, HORIZON EUROPE Framework Programme, Engineering and Physical Sciences Research Council
Openalex Percentile: Top 12%
Micro and Nano Robotics
2.18
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.