Genotoxicity and safety profile of Eleview®: A submucosal injectable composition for endoscopic mucosal resection and endoscopic submucosal dissection

Background and Objectives: Eleview® submucosal injectable composition with methylene blue (MB), is intended for use in gastrointestinal endoscopic procedures. Given the recognised in vitro mutagenicity of MB, Eleview® mutagenic and genotoxic potentials and its safety profile in acute and subacute toxicity settings were assessed. Methods: Acute and subacute systemic toxicity were tested in rats and dogs, respectively. Ames test and chromosome aberration test in Chinese Hamster V79 cells, were performed. The ratio of polychromatic to normochromatic erythrocytes was assessed in rat bone marrow at the rat MTD. Results: Eleview® oral or intraperitoneal at 20 mL/kg or 50 mL/kg did not induce any acute toxic effects in rats. In dogs, Eleview® (15 mL) did not cause any relevant in-life observations or any histopathological changes in any organs/tissues or injection sites. Ames test demonstrated no concentration-related and reproducible increases in revertant colony numbers. No significant increase of chromosomally aberrant cells was noted in Chinese Hamster cells. Lastly, Eleview® did not elicit significant increase in micronucleated polychromatic erythrocyte frequency. Conclusion: No death or abnormal findings in the acute and subacute studies were observed for Eleview® administration. Eleview® is not genotoxic, nor mutagenic, proving to be a safe medical device to use in clinical practice.

Authors

Publication Details

Journal
Gastrointestinal Tract
Published
2024-10-14
DOI
https://doi.org/10.54844/git.2024.583
Primary Topic
Gastric Cancer Management and Outcomes
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Genotoxicity and safety profile of Eleview®: A submucosal injectable composition for endoscopic mucosal resection and endoscopic submucosal dissection

Luigi Longo, Mara Gerloni, Gordon Alton, Alberto Morisetti
Gastrointestinal Tract
Gastric Cancer Management and Outcomes
article

Genotoxicity and safety profile of Eleview®: A submucosal injectable composition for endoscopic mucosal resection and endoscopic submucosal dissection

Luigi Longo, Mara Gerloni, Gordon Alton, Alberto Morisetti
article en

Abstract

Background and Objectives: Eleview® submucosal injectable composition with methylene blue (MB), is intended for use in gastrointestinal endoscopic procedures. Given the recognised in vitro mutagenicity of MB, Eleview® mutagenic and genotoxic potentials and its safety profile in acute and subacute toxicity settings were assessed. Methods: Acute and subacute systemic toxicity were tested in rats and dogs, respectively. Ames test and chromosome aberration test in Chinese Hamster V79 cells, were performed. The ratio of polychromatic to normochromatic erythrocytes was assessed in rat bone marrow at the rat MTD. Results: Eleview® oral or intraperitoneal at 20 mL/kg or 50 mL/kg did not induce any acute toxic effects in rats. In dogs, Eleview® (15 mL) did not cause any relevant in-life observations or any histopathological changes in any organs/tissues or injection sites. Ames test demonstrated no concentration-related and reproducible increases in revertant colony numbers. No significant increase of chromosomally aberrant cells was noted in Chinese Hamster cells. Lastly, Eleview® did not elicit significant increase in micronucleated polychromatic erythrocyte frequency. Conclusion: No death or abnormal findings in the acute and subacute studies were observed for Eleview® administration. Eleview® is not genotoxic, nor mutagenic, proving to be a safe medical device to use in clinical practice.

Gastrointestinal TractVol. 2(1)
Good health and well-being
Openalex Percentile: Top 67%
Gastric Cancer Management and Outcomes
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.