Swellable Biopolymer Composite Microneedle Patch for Pain‐Free Collection of Interstitial Fluid to Analyze Multiple Biomolecules

Sampling of interstitial fluid (ISF) using microneedle (MN) patch offers a pain-free minimally invasive alternative to syringe needle-based blood sample collection. However, there is a challenge in the development of MN patch that provides swelling behavior with sufficient mechanical strength for skin penetration. Here, we report fabrication of MN patch made of biopolymer composite containing iota-carrageenan, gelatin, and polyethylene glycol. Calcium chloride was used as a crosslinker to improve mechanical strength. MN patch was characterized for integrity, swelling behavior, mechanical strength, aspiration of fluid from agarose gel, and the excised porcine ear skin. An array of 361 MNs was able to aspirate 36 ± 5 and 14 ± 1 μL fluid after application in agarose gel matrix and the ex vivo porcine skin model, respectively. MN patch applied in vivo rat model for 30 min resulted in the collection of ISF containing 267 ± 128 mg/dL, 24 ± 13 mg/dL, and 0.6 ± 0.4 mIU/mL of glucose, uric acid and thyroid stimulating hormone (TSH), respectively. The concentration of glucose, uric acid, and TSH in rat blood was found to be 199 ± 47 mg/dL, 8.4 ± 6 mg/dL, and 1.1 ± 0.6 mIU/mL at the same time. Furthermore, MN patch applied on the forearm of 10 healthy human volunteers for 30 min was able to aspirate 32 ± 14 μL of ISF. The concentration of glucose, uric acid, and TSH determined from ISF samples of human volunteers was 64 ± 25 mg/dL, 4.2 ± 4.1 mg/dL, and 0.16 ± 0.08 mIU/mL, respectively. The visual analogue scale (VAS) pain score after MN application was lower compared with hypodermic syringe needle insertion. Taken together, biopolymer composite-based swellable MN patch can be developed for collection of ISF for simultaneous determination of multiple biomolecules in a minimally invasive manner.

Authors

Institutions

Publication Details

Journal
Journal of Biomedical Materials Research Part A
Published
2024-10-13
DOI
https://doi.org/10.1002/jbm.a.37809
Citations
7
Primary Topic
Advancements in Transdermal Drug Delivery
Type
article
Field-Weighted Citation Impact
1.46

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Swellable Biopolymer Composite Microneedle Patch for Pain‐Free Collection of Interstitial Fluid to Analyze Multiple Biomolecules

Aditi Prasad, Venkata Vamsi Krishna Venuganti, Shreya Shashank Chauhan
7 citations
Journal of Biomedical Materials Research Part A
Advancements in Transdermal Drug Delivery
1.46
article

Swellable Biopolymer Composite Microneedle Patch for Pain‐Free Collection of Interstitial Fluid to Analyze Multiple Biomolecules

Aditi Prasad, Venkata Vamsi Krishna Venuganti, Shreya Shashank Chauhan
article en
7 citations

Abstract

Sampling of interstitial fluid (ISF) using microneedle (MN) patch offers a pain-free minimally invasive alternative to syringe needle-based blood sample collection. However, there is a challenge in the development of MN patch that provides swelling behavior with sufficient mechanical strength for skin penetration. Here, we report fabrication of MN patch made of biopolymer composite containing iota-carrageenan, gelatin, and polyethylene glycol. Calcium chloride was used as a crosslinker to improve mechanical strength. MN patch was characterized for integrity, swelling behavior, mechanical strength, aspiration of fluid from agarose gel, and the excised porcine ear skin. An array of 361 MNs was able to aspirate 36 ± 5 and 14 ± 1 μL fluid after application in agarose gel matrix and the ex vivo porcine skin model, respectively. MN patch applied in vivo rat model for 30 min resulted in the collection of ISF containing 267 ± 128 mg/dL, 24 ± 13 mg/dL, and 0.6 ± 0.4 mIU/mL of glucose, uric acid and thyroid stimulating hormone (TSH), respectively. The concentration of glucose, uric acid, and TSH in rat blood was found to be 199 ± 47 mg/dL, 8.4 ± 6 mg/dL, and 1.1 ± 0.6 mIU/mL at the same time. Furthermore, MN patch applied on the forearm of 10 healthy human volunteers for 30 min was able to aspirate 32 ± 14 μL of ISF. The concentration of glucose, uric acid, and TSH determined from ISF samples of human volunteers was 64 ± 25 mg/dL, 4.2 ± 4.1 mg/dL, and 0.16 ± 0.08 mIU/mL, respectively. The visual analogue scale (VAS) pain score after MN application was lower compared with hypodermic syringe needle insertion. Taken together, biopolymer composite-based swellable MN patch can be developed for collection of ISF for simultaneous determination of multiple biomolecules in a minimally invasive manner.

Journal of Biomedical Materials Research Part AVol. 113(1)
Birla Institute of Technology and Science - Hyderabad Campus (IN)
Indian Council of Medical Research
Openalex Percentile: Top 20%
Advancements in Transdermal Drug Delivery
1.46
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.