Assessment of the carcinogenic potential of particulate matter generated from 3D printing devices in Balb/c 3T3-1-1 cells

Recently, there have been reports of sarcoma occurring in a Korean science teachers who used a 3D printer with acrylonitrile butadiene styrene (ABS) and polylactic acid (PLA) filaments for educational purposes. However, limited toxicological research data on 3D printing make it challenging to confirm a causal relationship between 3D printing and cancer. Therefore, occupational accidents involving teachers who have developed sarcoma have not been officially recognized. To address this gap, we aimed to evaluate the carcinogenic potential of particulate matter produced from ABS and PLA filaments commonly used in 3D printing. We created a generator mimicking 3D printing to generate particulate matter, which was used as an experimental material. The collected particulate matter was exposed to an in vitro system to investigate genetic damage, effects on cell transformation, and changes in carcinogenesis-related genes. Various assays, such as the comet assay, cell transformation assays, microarray analysis, and glucose consumption measurement, were employed. Cytotoxicity tests performed to determine the exposure concentration for the comet assay showed that cell viability was 83.6, 62.6, 42.0, and 10.2% for ABS at exposure concentrations of 50, 100, 200, and 400 µg/mL, respectively. PLA showed 91.7, 80.3, 65.1, and 60.8% viability at exposure concentrations of 50, 100, 200, and 400 µg/mL, respectively. Therefore, 50 µg/mL was set as the highest concentration for both ABS and PLA, and 25 and 12.5 µg/mL were set as the medium and low concentrations, respectively. The comet assay showed no changes in genetic damage caused by the particulate matter. Cytotoxicity results performed to establish exposure concentrations in the transformation assay showed that ABS showed cell viability of 88.0, 77.4, 84.7, and 85.5% at concentrations of 1.25, 2.5, 5, and 10 µg/mL, respectively, but few cells survived at concentrations above 20 µg/mL. PLA showed minimal cytotoxicity up to a concentration of 20 µg/ml. Therefore, in the cell transformation assay, a concentration of 10 µg/mL for ABS and 20 µg/mL for PLA was set as the highest exposure concentration, followed by medium and low exposure concentrations with a common ratio of 2. In cell transformation assays, only one transformed focus each was observed for both ABS and PLA particulate matter-exposed cells. The microarray assay revealed changes in gene expression, with a 41.7% change at 10 µg/mL for ABS and an 18.6% change at 20 µg/mL for PLA compared to the positive control group. Analysis of carcinogenesis-related gene expression changes on days 1, 7, and 25 of the promotion phase revealed that in cells exposed to 5 µg/mL of ABS, RBM3 gene expression increased by 3.66, 3.26, and 3.74 times, respectively, while MPP6 gene expression decreased by 0.33, 0.28, and 0.38 times, respectively, compared to the negative control group. Additionally, the measurement of glucose consumption showed that it increased in cells exposed to ABS and PLA particulate matter. Our findings suggest that the carcinogenic potential of ABS- and PLA-derived particulate matter in 3D printing cannot be completely ruled out. Therefore, further research in other test systems and analysis of additional parameters related to carcinogenesis, are deemed necessary to evaluate the carcinogenic risk of 3D printers using these materials.

Authors

Institutions

Publication Details

Journal
Scientific Reports
Published
2024-10-14
DOI
https://doi.org/10.1038/s41598-024-75491-1
Citations
4
Primary Topic
Additive Manufacturing and 3D Printing Technologies
Type
article
Field-Weighted Citation Impact
0.81

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Assessment of the carcinogenic potential of particulate matter generated from 3D printing devices in Balb/c 3T3-1-1 cells

Dong-Seok Seo, C. H. Lim
4 citations
Scientific Reports
Additive Manufacturing and 3D Printing Technologies
0.81
article

Assessment of the carcinogenic potential of particulate matter generated from 3D printing devices in Balb/c 3T3-1-1 cells

Dong-Seok Seo, C. H. Lim
article en
4 citations

Abstract

Recently, there have been reports of sarcoma occurring in a Korean science teachers who used a 3D printer with acrylonitrile butadiene styrene (ABS) and polylactic acid (PLA) filaments for educational purposes. However, limited toxicological research data on 3D printing make it challenging to confirm a causal relationship between 3D printing and cancer. Therefore, occupational accidents involving teachers who have developed sarcoma have not been officially recognized. To address this gap, we aimed to evaluate the carcinogenic potential of particulate matter produced from ABS and PLA filaments commonly used in 3D printing. We created a generator mimicking 3D printing to generate particulate matter, which was used as an experimental material. The collected particulate matter was exposed to an in vitro system to investigate genetic damage, effects on cell transformation, and changes in carcinogenesis-related genes. Various assays, such as the comet assay, cell transformation assays, microarray analysis, and glucose consumption measurement, were employed. Cytotoxicity tests performed to determine the exposure concentration for the comet assay showed that cell viability was 83.6, 62.6, 42.0, and 10.2% for ABS at exposure concentrations of 50, 100, 200, and 400 µg/mL, respectively. PLA showed 91.7, 80.3, 65.1, and 60.8% viability at exposure concentrations of 50, 100, 200, and 400 µg/mL, respectively. Therefore, 50 µg/mL was set as the highest concentration for both ABS and PLA, and 25 and 12.5 µg/mL were set as the medium and low concentrations, respectively. The comet assay showed no changes in genetic damage caused by the particulate matter. Cytotoxicity results performed to establish exposure concentrations in the transformation assay showed that ABS showed cell viability of 88.0, 77.4, 84.7, and 85.5% at concentrations of 1.25, 2.5, 5, and 10 µg/mL, respectively, but few cells survived at concentrations above 20 µg/mL. PLA showed minimal cytotoxicity up to a concentration of 20 µg/ml. Therefore, in the cell transformation assay, a concentration of 10 µg/mL for ABS and 20 µg/mL for PLA was set as the highest exposure concentration, followed by medium and low exposure concentrations with a common ratio of 2. In cell transformation assays, only one transformed focus each was observed for both ABS and PLA particulate matter-exposed cells. The microarray assay revealed changes in gene expression, with a 41.7% change at 10 µg/mL for ABS and an 18.6% change at 20 µg/mL for PLA compared to the positive control group. Analysis of carcinogenesis-related gene expression changes on days 1, 7, and 25 of the promotion phase revealed that in cells exposed to 5 µg/mL of ABS, RBM3 gene expression increased by 3.66, 3.26, and 3.74 times, respectively, while MPP6 gene expression decreased by 0.33, 0.28, and 0.38 times, respectively, compared to the negative control group. Additionally, the measurement of glucose consumption showed that it increased in cells exposed to ABS and PLA particulate matter. Our findings suggest that the carcinogenic potential of ABS- and PLA-derived particulate matter in 3D printing cannot be completely ruled out. Therefore, further research in other test systems and analysis of additional parameters related to carcinogenesis, are deemed necessary to evaluate the carcinogenic risk of 3D printers using these materials.

Scientific ReportsVol. 14(1)
Korea Occupational Safety and Health Agency (KR)
Occupational Safety and Health Research Institute
Openalex Percentile: Top 28%
Additive Manufacturing and 3D Printing Technologies
0.81
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.