B<sub>4</sub>C‐Assisted Paper Spray Ionization Mass Spectrometry

A novel inorganic nonmetallic material boron carbide (B<sub>4</sub>C) was applied in paper spray ionization to analyze organic molecules in both negative and positive modes. The utilization of B<sub>4</sub>C has led to a notable enhancement in signal responses for various molecules, including bisphenols and drugs, by approximately two to four times. The limit of detection (LOD) of bisphenol AF and nilotinib standard solutions can reach 1 and 0.5 μg/mL, respectively. Moreover, linear relationships for bisphenol AF was established within the concentration range of 1-100 μg/mL, exhibiting strong correlation coefficients. Recovery experiments for BPAF in water samples from the inlet and outlet of a sewage treatment plant, conducted without any pretreatment, achieved a maximum recovery rate of 98.8% and an RSD below 9.78%.

Authors

Institutions

Publication Details

Journal
Journal of Mass Spectrometry
Published
2024-10-13
DOI
https://doi.org/10.1002/jms.5098
Citations
3
Primary Topic
Mass Spectrometry Techniques and Applications
Type
article
Field-Weighted Citation Impact
0.72

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

B4C‐Assisted Paper Spray Ionization Mass Spectrometry

Lingpeng Zhan, Lulu Yu, Peiqi Luo, D. Hu et al.
3 citations
Journal of Mass Spectrometry
Mass Spectrometry Techniques and Applications
0.72
article

B4C‐Assisted Paper Spray Ionization Mass Spectrometry

Lingpeng Zhan, Lulu Yu, Peiqi Luo, D. Hu, Zijian Wei
article en
3 citations

Abstract

A novel inorganic nonmetallic material boron carbide (B<sub>4</sub>C) was applied in paper spray ionization to analyze organic molecules in both negative and positive modes. The utilization of B<sub>4</sub>C has led to a notable enhancement in signal responses for various molecules, including bisphenols and drugs, by approximately two to four times. The limit of detection (LOD) of bisphenol AF and nilotinib standard solutions can reach 1 and 0.5 μg/mL, respectively. Moreover, linear relationships for bisphenol AF was established within the concentration range of 1-100 μg/mL, exhibiting strong correlation coefficients. Recovery experiments for BPAF in water samples from the inlet and outlet of a sewage treatment plant, conducted without any pretreatment, achieved a maximum recovery rate of 98.8% and an RSD below 9.78%.

Journal of Mass SpectrometryVol. 59(11)
Guangxi University (CN), Shenzhen Bay Laboratory (CN)
Guangxi University, Specific Research Project of Guangxi for Research Bases and Talents
Clean water and sanitation
Openalex Percentile: Top 33%
Mass Spectrometry Techniques and Applications
0.72
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.