BackgroundAim of this study was to find out if the type of vascular prosthesis used, especially collagen impregnated polyester versus gelatin impregnated woven fabric graft, has any impact on the early postoperative bleeding rate, blood product consumption and re-thoracotomy rate in isolated ascending aortic surgery.Methods<i>n</i> = 46 consecutive patients who received a supra-commissural replacement of the ascending aorta between 01/2016 - 01/ 2021 were included in this retrospective single-center study. The underlying pathology was an aortic aneurysm in 36 (81 %) and/or an acute type A aortic dissection (ATAAD) limited to the ascending aorta in 7 (15 %) and/or a penetrating aortic ulcer (PAU) with intramural hematoma in 6 (13 %) patients. According to the type of vascular graft used, the cohort was divided as follows: 25 patients (54%) received a double velour woven, collagen impregnated polyester graft (Hemashield, Getinge; CI-Group) whereas in 21 patients (46 %) a gelatin impregnated woven fabric graft was used (Gelweave, Vascutek / Terumo; GI-group). As primary endpoints class 3 bleeding according to the Valve Academic Research Consortium (VARC3) criteria and freedom from re-intervention were assessed. As secondary endpoints, 30-day mortality and stroke were defined.ResultsPreoperative risk assessment (EuroSCORE II), gender-, BMI-stratification and NYHA-classification as well as mean CPB-times (114 ± 44 min vs 110 ± 48 min) and aortic cross-clamp times (71 ± 28 min vs 66 ± 30 min) were similar in both groups. Bleeding, measured by drainage volume output within the first postoperative 24 h (480 ± 426 mL vs 389 ± 169 mL), erythrocytes concentrate consumption (2,4 vs 2,3) and similar re-thoracotomy rates (4 vs 4.7 %) showed no difference between groups. 30- day mortality (12 vs 5 %; <i>p</i> = 0.614) and stroke rates (4 vs 9.5; <i>p</i> = 0,4) showed no differences between groups.ConclusionsRegarding postoperative bleeding no difference were seen between the two graft types. Long-term follow-up and larger prospective randomized studies are requested to prove these findings.

Authors

Institutions

Publication Details

Journal
Perfusion
Published
2024-10-13
DOI
https://doi.org/10.1177/02676591241291346
Primary Topic
Aortic Disease and Treatment Approaches
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Influence of vascular graft type for ascending aorta replacement on the early postoperative outcome

Comsa Horatiu, Ilija Djordjevic, Peter Haldenwang, Ihor Krasivskyi et al.
Perfusion
Aortic Disease and Treatment Approaches
article

Influence of vascular graft type for ascending aorta replacement on the early postoperative outcome

Comsa Horatiu, Ilija Djordjevic, Peter Haldenwang, Ihor Krasivskyi, Stephen Gerfer, Maximilian Luehr, Thorsten Wahlers, Alina Chigri, Justus Strauch
article en

Abstract

BackgroundAim of this study was to find out if the type of vascular prosthesis used, especially collagen impregnated polyester versus gelatin impregnated woven fabric graft, has any impact on the early postoperative bleeding rate, blood product consumption and re-thoracotomy rate in isolated ascending aortic surgery.Methods<i>n</i> = 46 consecutive patients who received a supra-commissural replacement of the ascending aorta between 01/2016 - 01/ 2021 were included in this retrospective single-center study. The underlying pathology was an aortic aneurysm in 36 (81 %) and/or an acute type A aortic dissection (ATAAD) limited to the ascending aorta in 7 (15 %) and/or a penetrating aortic ulcer (PAU) with intramural hematoma in 6 (13 %) patients. According to the type of vascular graft used, the cohort was divided as follows: 25 patients (54%) received a double velour woven, collagen impregnated polyester graft (Hemashield, Getinge; CI-Group) whereas in 21 patients (46 %) a gelatin impregnated woven fabric graft was used (Gelweave, Vascutek / Terumo; GI-group). As primary endpoints class 3 bleeding according to the Valve Academic Research Consortium (VARC3) criteria and freedom from re-intervention were assessed. As secondary endpoints, 30-day mortality and stroke were defined.ResultsPreoperative risk assessment (EuroSCORE II), gender-, BMI-stratification and NYHA-classification as well as mean CPB-times (114 ± 44 min vs 110 ± 48 min) and aortic cross-clamp times (71 ± 28 min vs 66 ± 30 min) were similar in both groups. Bleeding, measured by drainage volume output within the first postoperative 24 h (480 ± 426 mL vs 389 ± 169 mL), erythrocytes concentrate consumption (2,4 vs 2,3) and similar re-thoracotomy rates (4 vs 4.7 %) showed no difference between groups. 30- day mortality (12 vs 5 %; <i>p</i> = 0.614) and stroke rates (4 vs 9.5; <i>p</i> = 0,4) showed no differences between groups.ConclusionsRegarding postoperative bleeding no difference were seen between the two graft types. Long-term follow-up and larger prospective randomized studies are requested to prove these findings.

PerfusionVol. 40(5)
University of Cologne (DE), University Hospital Bonn (DE), St. Josef-Hospital (DE), BG University Hospital Bergmannsheil Bochum (DE), University Hospital Cologne (DE), Ruhr University Bochum (DE)
Good health and well-being
Openalex Percentile: Top 67%
Aortic Disease and Treatment Approaches
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.