Rapid Detection of ppt Concentration of Perfluorooctane Sulfonate in Water by Quartz Crystal Microbalance Loaded with MOF-808

Identifying trace levels of perfluorooctane sulfonate (PFOS) at parts per trillion (ppt) in water remains a formidable task. Here, we fabricated MOF-808 through rapid microwave synthesis. Characterization of the synthesized MOF-808 involved techniques including XRD, FT-IR, SEM, and nitrogen sorption analysis. We integrated the MOF-808 as the sensing layer in a quartz crystal microbalance (QCM) sensor, specifically tailored for PFOS detection in water. Our findings revealed that the QCM sensor can detect 10 ppt of PFOS when the frequency shift is approximately 90 Hz within 50 s. Moreover, the continuous response, selectivity, and anti-interference capability of the sensor were systematically explored. This study introduces a pioneering approach for detecting ppt concentrations of PFOS in water, offering significant prospects for future applications and dissemination.

Authors

Institutions

Publication Details

Journal
Russian Journal of Inorganic Chemistry
Published
2024-10-11
DOI
https://doi.org/10.1134/s0036023624602460
Citations
3
Primary Topic
Gas Sensing Nanomaterials and Sensors
Type
article
Field-Weighted Citation Impact
0.63
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Rapid Detection of ppt Concentration of Perfluorooctane Sulfonate in Water by Quartz Crystal Microbalance Loaded with MOF-808

Luyu Wang, Chunyang Yu, Jia Tao Song, Chenghai Ruan
3 citations
Russian Journal of Inorganic Chemistry
Gas Sensing Nanomaterials and Sensors
0.63
article

Rapid Detection of ppt Concentration of Perfluorooctane Sulfonate in Water by Quartz Crystal Microbalance Loaded with MOF-808

Luyu Wang, Chunyang Yu, Jia Tao Song, Chenghai Ruan
article en
3 citations

Abstract

Identifying trace levels of perfluorooctane sulfonate (PFOS) at parts per trillion (ppt) in water remains a formidable task. Here, we fabricated MOF-808 through rapid microwave synthesis. Characterization of the synthesized MOF-808 involved techniques including XRD, FT-IR, SEM, and nitrogen sorption analysis. We integrated the MOF-808 as the sensing layer in a quartz crystal microbalance (QCM) sensor, specifically tailored for PFOS detection in water. Our findings revealed that the QCM sensor can detect 10 ppt of PFOS when the frequency shift is approximately 90 Hz within 50 s. Moreover, the continuous response, selectivity, and anti-interference capability of the sensor were systematically explored. This study introduces a pioneering approach for detecting ppt concentrations of PFOS in water, offering significant prospects for future applications and dissemination.

Russian Journal of Inorganic ChemistryVol. 69(13)
Shanghai Jiao Tong University (CN), China Academy of Art (CN), Zhejiang Gongshang University Hangzhou College of Commerce, Zhejiang Gongshang University (CN)
Clean water and sanitation
Openalex Percentile: Top 31%
Gas Sensing Nanomaterials and Sensors
0.63
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.