Clinical Evaluation of a Novel Compression Device For Ultrasound-Guided Repair of Femoral Artery Pseudoaneurysms: A Double-Blind Clinical Trial

Background: Femoral artery pseudoaneurysm is a well-known complication after conventional angiography. Today, the treatment of choice for this condition is noninvasive repair using manual ultrasound-guided compression. Objectives: This study aimed to evaluate the efficacy of a novel compression device in improving angiography-induced pseudoaneurysm treatment compared to manual ultrasound-guided compression repair. Patients and Method: A double-blind, randomized clinical trial was performed on patients with femoral angiography-induced pseudoaneurysm in the Radiology Department of Ghaem Hospital, Mashhad, Iran. Based on color Doppler ultrasound exams, patients diagnosed with a pseudoaneurysm within 72 hours of angiography were included in the study. Patients were excluded if they had complete blockage, complete pseudoaneurysm thrombosis, abscess, surface tissue infection, or open wound in the area. The patients were allocated to a manual ultrasound-guided compression group or a device-assisted compression group using simple randomization with a sealed envelope method. After collecting demographic data, the patients underwent an ultrasound exam of the groin to determine and record the size of the pseudoaneurysm and the ratio of thrombosis to open lumen. The therapeutic success rate was defined as complete lumen thrombosis after conducting the compression procedure one to three times. Also, the pain score was measured during compression using the Visual Analog Scale based on a scale of 0 - 10. The duration of successful procedures was also documented. The patients were monitored for 6 hours for any side effects. The level of statistical significance was set at P < 0.05 for all tests. Results: The study was performed on 22 patients (13 males/9 females) with a mean age of 65.5 ± 3.5 years divided into two groups of device-assisted (n = 11) and manual ultrasound-guided (n = 11) compression repair. The two groups did not differ significantly in terms of demographic variables or initial ultrasound variables associated with the pseudoaneurysm. The device-assisted compression group was found to have lower pain intensity (5.0 ± 1.0 vs. 6.0 ± 0.8; P = 0.024) and a significantly higher success rate (100% vs. 45.5%; P = 0.004) compared to the manual compression group. None of the patients showed any side effects. Conclusion: This preliminary study showed that the proposed device is completely safe and may improve the success rate while decreasing pain scores during ultrasound-guided compression procedures. Using a large multicenter study design, evaluating the efficacy of the novel device for hemostasis during sheath removal and adding new equipment to the device, such as manometers to apply controlled pressure, are suggested for future studies.

Authors

Institutions

Publication Details

Journal
Iranian Journal of Radiology
Published
2024-10-13
DOI
https://doi.org/10.5812/iranjradiol-146118
Primary Topic
Vascular Procedures and Complications
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Clinical Evaluation of a Novel Compression Device For Ultrasound-Guided Repair of Femoral Artery Pseudoaneurysms: A Double-Blind Clinical Trial

Niloufar Nazeri, Soroosh Dehghani, Zahra Haeri Kermani, Negar Nekooei et al.
Iranian Journal of Radiology
Vascular Procedures and Complications
article

Clinical Evaluation of a Novel Compression Device For Ultrasound-Guided Repair of Femoral Artery Pseudoaneurysms: A Double-Blind Clinical Trial

Niloufar Nazeri, Soroosh Dehghani, Zahra Haeri Kermani, Negar Nekooei, Mohammad Reza Yousefi Rudsari, Sirous Nekooei
article en

Abstract

Background: Femoral artery pseudoaneurysm is a well-known complication after conventional angiography. Today, the treatment of choice for this condition is noninvasive repair using manual ultrasound-guided compression. Objectives: This study aimed to evaluate the efficacy of a novel compression device in improving angiography-induced pseudoaneurysm treatment compared to manual ultrasound-guided compression repair. Patients and Method: A double-blind, randomized clinical trial was performed on patients with femoral angiography-induced pseudoaneurysm in the Radiology Department of Ghaem Hospital, Mashhad, Iran. Based on color Doppler ultrasound exams, patients diagnosed with a pseudoaneurysm within 72 hours of angiography were included in the study. Patients were excluded if they had complete blockage, complete pseudoaneurysm thrombosis, abscess, surface tissue infection, or open wound in the area. The patients were allocated to a manual ultrasound-guided compression group or a device-assisted compression group using simple randomization with a sealed envelope method. After collecting demographic data, the patients underwent an ultrasound exam of the groin to determine and record the size of the pseudoaneurysm and the ratio of thrombosis to open lumen. The therapeutic success rate was defined as complete lumen thrombosis after conducting the compression procedure one to three times. Also, the pain score was measured during compression using the Visual Analog Scale based on a scale of 0 - 10. The duration of successful procedures was also documented. The patients were monitored for 6 hours for any side effects. The level of statistical significance was set at P < 0.05 for all tests. Results: The study was performed on 22 patients (13 males/9 females) with a mean age of 65.5 ± 3.5 years divided into two groups of device-assisted (n = 11) and manual ultrasound-guided (n = 11) compression repair. The two groups did not differ significantly in terms of demographic variables or initial ultrasound variables associated with the pseudoaneurysm. The device-assisted compression group was found to have lower pain intensity (5.0 ± 1.0 vs. 6.0 ± 0.8; P = 0.024) and a significantly higher success rate (100% vs. 45.5%; P = 0.004) compared to the manual compression group. None of the patients showed any side effects. Conclusion: This preliminary study showed that the proposed device is completely safe and may improve the success rate while decreasing pain scores during ultrasound-guided compression procedures. Using a large multicenter study design, evaluating the efficacy of the novel device for hemostasis during sheath removal and adding new equipment to the device, such as manometers to apply controlled pressure, are suggested for future studies.

Iranian Journal of RadiologyVol. 21(2)
Mashhad University of Medical Sciences (IR), Ghaem Hospital (IR)
Openalex Percentile: Top 67%
Vascular Procedures and Complications
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.