Angle Sensor for Minimally Invasive Surgical Robot Based on Surface Plasmon Resonance with Kretschmann Prisms

This study proposes a bimetallic Ag-Au sensor through a comparative analysis with traditional Ag-only membrane sensors and Au-only membrane SPR sensors. Innovative use of SPR sensors for angular change measurement, especially in minimally invasive robotic surgery in medicine. The research findings indicate that the Ag film sensor exhibits the highest sensitivity, while the bimetallic Ag-Au sensor demonstrates superior sensitivity compared to the Au-only sensor. Furthermore, the stability of the bimetallic Ag-Au sensor surpasses that of the Ag-only sensor. After evaluating the performance parameters based on experimental and simulation results, the sensor with 40 nm Ag and 10 nm Au film thickness is identified as the optimal design. Experimentally verified, this configuration yielded the best sensing performance, with a sensitivity of 628.95 for changes in folding angle. This represents a 275.64% improvement over the pure Au sensor and a 210.43% enhancement over the pure Ag sensor in terms of sensitivity for angle changes.

Authors

Institutions

Publication Details

Journal
Plasmonics
Published
2024-10-12
DOI
https://doi.org/10.1007/s11468-024-02471-6
Citations
2
Primary Topic
Photonic and Optical Devices
Type
article
Field-Weighted Citation Impact
0.42
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Angle Sensor for Minimally Invasive Surgical Robot Based on Surface Plasmon Resonance with Kretschmann Prisms

Jinhong Pan, Yanpei Xu, Meng Sun, Qi Wang et al.
2 citations
Plasmonics
Photonic and Optical Devices
0.42
article

Angle Sensor for Minimally Invasive Surgical Robot Based on Surface Plasmon Resonance with Kretschmann Prisms

Jinhong Pan, Yanpei Xu, Meng Sun, Qi Wang, Heya Zheng
article en
2 citations

Abstract

This study proposes a bimetallic Ag-Au sensor through a comparative analysis with traditional Ag-only membrane sensors and Au-only membrane SPR sensors. Innovative use of SPR sensors for angular change measurement, especially in minimally invasive robotic surgery in medicine. The research findings indicate that the Ag film sensor exhibits the highest sensitivity, while the bimetallic Ag-Au sensor demonstrates superior sensitivity compared to the Au-only sensor. Furthermore, the stability of the bimetallic Ag-Au sensor surpasses that of the Ag-only sensor. After evaluating the performance parameters based on experimental and simulation results, the sensor with 40 nm Ag and 10 nm Au film thickness is identified as the optimal design. Experimentally verified, this configuration yielded the best sensing performance, with a sensitivity of 628.95 for changes in folding angle. This represents a 275.64% improvement over the pure Au sensor and a 210.43% enhancement over the pure Ag sensor in terms of sensitivity for angle changes.

PlasmonicsVol. 20(6)
Northeastern University (CN)
Openalex Percentile: Top 37%
Photonic and Optical Devices
0.42
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.