The effect of source step size in uterine cervix intracavitary with high dose rate (HDR) Brachytherapy: A dosimetric comparative study.-

The presented study discusses the impact of source step size on dose distribution in patients undergoing high-dose-rate after-loading Brachytherapy with cobalt-60 (Co-60) for cervical cancer (Ca-cx). Flexitron® Cobalt-60 HDR Brachytherapy unit with Co-60 source, which has an active core 0.5 mm diameter and 3.5 mm active core length was used. Oncertra® Brachy v4.6, (Elekta, Stockholm, Sweden) treatment planning system was also used in patient dose distribution and calculation. The respective study is based on the database of 11 patients Ca-cx already treated with Co-60 intracavitary Brachytherapy with 21 Gy treatment doses for each patient delivered in three fractions after a 45 Gy of external beam radiotherapy. The assessment of the entire treatment process included an examination of the prescribed dose volume, organ-at-risk doses, and treatment time. This analysis was performed for varying source step sizes 1 mm, 3 mm, 5 mm, and 7 mm considering each patient individually. our general results we can conclude that 5 mm step size is the best choice to do brachytherapy plan to achieve organ at risk constrains, treatment time and prescribed dose coverage volume were affected by the increase of source step size.

Authors

Institutions

Publication Details

Journal
Arab Journal of Nuclear Sciences and Applications
Published
2024-10-01
DOI
https://doi.org/10.21608/ajnsa.2024.301034.1828
Primary Topic
Endometrial and Cervical Cancer Treatments
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

The effect of source step size in uterine cervix intracavitary with high dose rate (HDR) Brachytherapy: A dosimetric comparative study.-

Mahmoud H. Abdelgawad, A. H. Said, Mohamed Mahmoud Abdelhakim, Amna Abdelrahim Mohamed et al.
Arab Journal of Nuclear Sciences and Applications
Endometrial and Cervical Cancer Treatments
article

The effect of source step size in uterine cervix intracavitary with high dose rate (HDR) Brachytherapy: A dosimetric comparative study.-

Mahmoud H. Abdelgawad, A. H. Said, Mohamed Mahmoud Abdelhakim, Amna Abdelrahim Mohamed, Shaban Harb
article en

Abstract

The presented study discusses the impact of source step size on dose distribution in patients undergoing high-dose-rate after-loading Brachytherapy with cobalt-60 (Co-60) for cervical cancer (Ca-cx). Flexitron® Cobalt-60 HDR Brachytherapy unit with Co-60 source, which has an active core 0.5 mm diameter and 3.5 mm active core length was used. Oncertra® Brachy v4.6, (Elekta, Stockholm, Sweden) treatment planning system was also used in patient dose distribution and calculation. The respective study is based on the database of 11 patients Ca-cx already treated with Co-60 intracavitary Brachytherapy with 21 Gy treatment doses for each patient delivered in three fractions after a 45 Gy of external beam radiotherapy. The assessment of the entire treatment process included an examination of the prescribed dose volume, organ-at-risk doses, and treatment time. This analysis was performed for varying source step sizes 1 mm, 3 mm, 5 mm, and 7 mm considering each patient individually. our general results we can conclude that 5 mm step size is the best choice to do brachytherapy plan to achieve organ at risk constrains, treatment time and prescribed dose coverage volume were affected by the increase of source step size.

Arab Journal of Nuclear Sciences and ApplicationsVol. 57(4)
Cairo University (EG), South Valley University (EG), Al-Azhar University (ID)
Zero hunger
Openalex Percentile: Top 72%
Endometrial and Cervical Cancer Treatments
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.