Water Contamination at an Ambulatory Surgical Center Leads to Severe Mycobacterium Fortuitum Prosthetic Joint Infections: A Case Series
Prosthetic joint infections (PJIs) following total joint arthroplasties are relatively rare but devastating complications. To date, no cases of <i>Mycobacterium fortuitum</i> PJIs associated with contaminated water supplies have been reported in the literature. Our report details 5 patients with <i>Mycobacterium fortuitum</i> PJIs related to a contaminated water supply at an ambulatory surgical center. These patients were identified by referral to our academic center. All underwent at least 1 revision surgery prior to referral and required prolonged broad-spectrum antibiotics. All had extensive wound complications, and 4 of 5 patients have received at least stage 1 of a 2-stage revision. All will require further surgery, but long-term outcomes remain relatively uncertain.
Authors
- Reece Vesperman (ORCID: https://orcid.org/0009-0008-7107-3801)
- J Ryan Martin (ORCID: https://orcid.org/0000-0002-4125-2154)
- Stephen M. Engstrom
- Christina T. Fiske (ORCID: https://orcid.org/0000-0003-2165-7354)
- Jessica L. Rice (ORCID: https://orcid.org/0000-0002-3346-3963)
- Logan M Locascio
Institutions
- Vanderbilt University (US)
- Vanderbilt University Medical Center (US)
Publication Details
- Journal
- Arthroplasty Today
- Published
- 2024-10-12
- DOI
- https://doi.org/10.1016/j.artd.2024.101520
- Citations
- 1
- Primary Topic
- Orthopedic Infections and Treatments
- Type
- article
- Field-Weighted Citation Impact
- 0.57