Monitoring system for electrical load usage characteristics in electrical engineering building

Electrical energy is becoming increasingly essential for educational activities in electrical engineering facilities, as these activities include the use of electrical equipment. The quantity of electrical loads in buildings escalates annually, resulting in increased demand on existing lines and the original design of building construction. Nonetheless, the positioning and allocation of the load within the panel do not align with the augmentation of the load. Consequently, the load becomes uneven across all three stages. Phase T is experiencing an overload, while Phase R has a lesser burden compared to Phases S and T. The maximum current in Phase T is 36.3 A; the imbalance is excessive, leading to a neutral current of 25.2 A. This is perilous since the present value at the neutral point ought to be zero; if the load remains unregulated, it will lead to a contact voltage in electrical apparatus. The utilization of cables is unsuitable due to the substantial connected load, while the cable diameter is merely 2.5 mm², capable of conducting a maximum current of 21 A. Therefore, it is imperative to reassess the electrical installation in the engineering building to avert short circuit disruptions.

Authors

Institutions

Publication Details

Journal
Edelweiss Applied Science and Technology
Published
2024-10-12
DOI
https://doi.org/10.55214/25768484.v8i6.2287
Primary Topic
Advanced Sensor and Control Systems
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Monitoring system for electrical load usage characteristics in electrical engineering building

Andik Bintoro, Zalfie Ardian, Teuku Multazam, Badriana Badriana et al.
Edelweiss Applied Science and Technology
Advanced Sensor and Control Systems
article

Monitoring system for electrical load usage characteristics in electrical engineering building

Andik Bintoro, Zalfie Ardian, Teuku Multazam, Badriana Badriana, Dahlan Abdullah
article en

Abstract

Electrical energy is becoming increasingly essential for educational activities in electrical engineering facilities, as these activities include the use of electrical equipment. The quantity of electrical loads in buildings escalates annually, resulting in increased demand on existing lines and the original design of building construction. Nonetheless, the positioning and allocation of the load within the panel do not align with the augmentation of the load. Consequently, the load becomes uneven across all three stages. Phase T is experiencing an overload, while Phase R has a lesser burden compared to Phases S and T. The maximum current in Phase T is 36.3 A; the imbalance is excessive, leading to a neutral current of 25.2 A. This is perilous since the present value at the neutral point ought to be zero; if the load remains unregulated, it will lead to a contact voltage in electrical apparatus. The utilization of cables is unsuitable due to the substantial connected load, while the cable diameter is merely 2.5 mm², capable of conducting a maximum current of 21 A. Therefore, it is imperative to reassess the electrical installation in the engineering building to avert short circuit disruptions.

Edelweiss Applied Science and TechnologyVol. 8(6)
Malikussaleh University (ID)
Affordable and clean energy
Openalex Percentile: Top 80%
Advanced Sensor and Control Systems
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.