Efficacy for aspiration prevention through thickening of liquid foods evaluated using a swallowing model apparatus

Abstract An apparatus simulating the swallowing process of liquid foods was constructed using a flow channel. In the channel, a circular cylindrical obstruction was fixed to serve as an epiglottis in the mesopharynx. The apparatus was designed with an adjustable gate for flow control to represent the processes of healthy swallowing and dysphagia. The parameters considered were the holding time and flow resistance controlled by the gate, which were assumed to indicate the swallowing reflex and power, respectively. When a Newtonian liquid with relatively low viscosity was used, the flow experiment performed using the apparatus under conditions of shorter holding time and larger flow resistance successfully reproduced a phenomenon similar to aspiration in a patient with dysphagia. In addition to a Newtonian liquid with high viscosity, non-Newtonian liquids thickened to various concentrations using commercially available thickeners were used. In flow experiments with these test liquids, the efficacy for aspiration prevention was inferred based not only on the viscosity of the liquid but also its elasticity, depending on its viscosity.

Authors

Institutions

Publication Details

Journal
International Journal of Food Engineering
Published
2024-10-01
DOI
https://doi.org/10.1515/ijfe-2024-0076
Primary Topic
Dysphagia Assessment and Management
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Efficacy for aspiration prevention through thickening of liquid foods evaluated using a swallowing model apparatus

Masanori Yoshida, Yuichiro Takako, Hiroshi Ono, Ryota Suzuki
International Journal of Food Engineering
Dysphagia Assessment and Management
article

Efficacy for aspiration prevention through thickening of liquid foods evaluated using a swallowing model apparatus

Masanori Yoshida, Yuichiro Takako, Hiroshi Ono, Ryota Suzuki
article en

Abstract

Abstract An apparatus simulating the swallowing process of liquid foods was constructed using a flow channel. In the channel, a circular cylindrical obstruction was fixed to serve as an epiglottis in the mesopharynx. The apparatus was designed with an adjustable gate for flow control to represent the processes of healthy swallowing and dysphagia. The parameters considered were the holding time and flow resistance controlled by the gate, which were assumed to indicate the swallowing reflex and power, respectively. When a Newtonian liquid with relatively low viscosity was used, the flow experiment performed using the apparatus under conditions of shorter holding time and larger flow resistance successfully reproduced a phenomenon similar to aspiration in a patient with dysphagia. In addition to a Newtonian liquid with high viscosity, non-Newtonian liquids thickened to various concentrations using commercially available thickeners were used. In flow experiments with these test liquids, the efficacy for aspiration prevention was inferred based not only on the viscosity of the liquid but also its elasticity, depending on its viscosity.

International Journal of Food EngineeringVol. 20(9-10)
Muroran Institute of Technology (JP)
Japan Society for the Promotion of Science
Openalex Percentile: Top 71%
Dysphagia Assessment and Management
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.