Grade I and Grade II Penile Strangulation From a Plastic Bottleneck

In this case report, we present two clinical cases of penile strangulation caused by a bottleneck at the base of the penis. In the first case, corporal aspiration was used to decrease the blood that is trapped in the corpora due to the constriction. A rotating saw was used to incise the bottleneck in a full-thickness manner. The plastic bottleneck was successfully incised and extricated with the rotating saw while the penile shaft was protected. This technique is novel and unique, as there are no prior instances in the literature where both corporal aspiration and a rotating saw were used simultaneously. In the second case, penile strangulation was resolved with a ring cutter, which allowed the bottleneck to be extricated without causing further laceration. Both the combined use of corporal aspiration and a rotating saw, as well as the utilization of a ring cutter, were efficacious approaches that led to immediate improvement in the patients.

Authors

Institutions

Publication Details

Journal
Cureus
Published
2024-10-12
DOI
https://doi.org/10.7759/cureus.71306
Primary Topic
Genital Health and Disease
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Grade I and Grade II Penile Strangulation From a Plastic Bottleneck

Bradley Buck, Ahmed El‐Zawahry, Wei Lu, SriGita Madiraju et al.
Cureus
Genital Health and Disease
article

Grade I and Grade II Penile Strangulation From a Plastic Bottleneck

Bradley Buck, Ahmed El‐Zawahry, Wei Lu, SriGita Madiraju, Robin Z Cheng
article en

Abstract

In this case report, we present two clinical cases of penile strangulation caused by a bottleneck at the base of the penis. In the first case, corporal aspiration was used to decrease the blood that is trapped in the corpora due to the constriction. A rotating saw was used to incise the bottleneck in a full-thickness manner. The plastic bottleneck was successfully incised and extricated with the rotating saw while the penile shaft was protected. This technique is novel and unique, as there are no prior instances in the literature where both corporal aspiration and a rotating saw were used simultaneously. In the second case, penile strangulation was resolved with a ring cutter, which allowed the bottleneck to be extricated without causing further laceration. Both the combined use of corporal aspiration and a rotating saw, as well as the utilization of a ring cutter, were efficacious approaches that led to immediate improvement in the patients.

CureusVol. 16(10)
Center for Special Minimally Invasive and Robotic Surgery (US), University of Toledo (US)
Openalex Percentile: Top 67%
Genital Health and Disease
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Grade I and Grade II Penile Strangulation From a Plastic Bottleneck — Bradley Buck, Ahmed El‐Zawahry, et al. · Cureus (2024) | TGRS Research Map | TGRS