In-tube extraction dynamic headspace coupled to gas chromatography-mass spectrometry for the sensitive analysis of volatile compounds in aqueous samples

Aim: Volatile organic compounds (VOCs) are often human-made contaminants used and generated in the manufacturing of numerous products, presenting notable environmental and health hazards. Therefore, the development of sensitive and reliable analytical methods is crucial for their detection with accuracy, timeliness, and automation capabilities. The objective of this study is to demonstrate the suitability of the in-tube extraction dynamic headspace (ITEX-DHS) sampling method for the gas chromatographic/mass spectrometric (GC/MS) analysis of BTEX (benzene, toluene, ethylbenzene, and xylenes) compounds in aqueous matrices. It emphasizes the method’s metrological reliability and innovative approach to precisely determining VOCs in aqueous environments providing a tool to prevent contamination of the agrifood sector. Methods: Following the optimization of various experimental parameters, including salt incorporation and adjustments of both dry purging and desorption conditions. The method’s performance was evaluated for repeatability, reproducibility, and robustness. Results: Limit of detection (LOD) and limit of quantification (LOQ) were for all substances determined lower than 50 and 100 ng/L, respectively. Average relative standard deviations below 5% were achieved for all analytes, with recovery rates ranging between 93% and 101%. Subsequently, the method was applied for the determination of BTEX in one hundred groundwater samples. The findings revealed that the BTEX levels were below the LOD in 84.2% of samples. However, in the remaining samples, more than one compound was detected at concentrations higher than the LOQ. Conclusions: The ITEX method emerges as a highly favorable alternative to both solid phase microextraction (SPME) and purge and trap (P & T) methods for determining BTEX in aqueous samples, providing significant advantages. Its strengths lie in its increased robustness, extended trap lifespan, and enhanced sensitivity, underscoring its superior performance in VOC analysis. The total analytical method allows the sensitive and robust determination of VOC.

Authors

Institutions

Publication Details

Journal
Exploration of Foods and Foodomics
Published
2024-10-12
DOI
https://doi.org/10.37349/eff.2024.00053
Primary Topic
Advanced Chemical Sensor Technologies
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

In-tube extraction dynamic headspace coupled to gas chromatography-mass spectrometry for the sensitive analysis of volatile compounds in aqueous samples

Urania Menkissoglu‐Spiroudi, Eleni Zymvrakaki, Nikos Anagnostou
Exploration of Foods and Foodomics
Advanced Chemical Sensor Technologies
article

In-tube extraction dynamic headspace coupled to gas chromatography-mass spectrometry for the sensitive analysis of volatile compounds in aqueous samples

Urania Menkissoglu‐Spiroudi, Eleni Zymvrakaki, Nikos Anagnostou
article en

Abstract

Aim: Volatile organic compounds (VOCs) are often human-made contaminants used and generated in the manufacturing of numerous products, presenting notable environmental and health hazards. Therefore, the development of sensitive and reliable analytical methods is crucial for their detection with accuracy, timeliness, and automation capabilities. The objective of this study is to demonstrate the suitability of the in-tube extraction dynamic headspace (ITEX-DHS) sampling method for the gas chromatographic/mass spectrometric (GC/MS) analysis of BTEX (benzene, toluene, ethylbenzene, and xylenes) compounds in aqueous matrices. It emphasizes the method’s metrological reliability and innovative approach to precisely determining VOCs in aqueous environments providing a tool to prevent contamination of the agrifood sector. Methods: Following the optimization of various experimental parameters, including salt incorporation and adjustments of both dry purging and desorption conditions. The method’s performance was evaluated for repeatability, reproducibility, and robustness. Results: Limit of detection (LOD) and limit of quantification (LOQ) were for all substances determined lower than 50 and 100 ng/L, respectively. Average relative standard deviations below 5% were achieved for all analytes, with recovery rates ranging between 93% and 101%. Subsequently, the method was applied for the determination of BTEX in one hundred groundwater samples. The findings revealed that the BTEX levels were below the LOD in 84.2% of samples. However, in the remaining samples, more than one compound was detected at concentrations higher than the LOQ. Conclusions: The ITEX method emerges as a highly favorable alternative to both solid phase microextraction (SPME) and purge and trap (P & T) methods for determining BTEX in aqueous samples, providing significant advantages. Its strengths lie in its increased robustness, extended trap lifespan, and enhanced sensitivity, underscoring its superior performance in VOC analysis. The total analytical method allows the sensitive and robust determination of VOC.

Exploration of Foods and FoodomicsVol. 2(6)
International Hellenic University (GR), Aristotle University of Thessaloniki (GR)
Aristotle University of Thessaloniki, Research Committee, Aristotle University of Thessaloniki
Clean water and sanitation
Openalex Percentile: Top 84%
Advanced Chemical Sensor Technologies
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.