Improvement of detector shield in PGNAA facility for boron concentration measurement

A radiation shield consists of borated polyethylene (7 % wt of boron) and lead was used for the HPGe detector in Isfahan MNSR's PGNAA facility in order to remove scattered neutrons and gamma rays, respectively. Therefore, the boron peak in gamma spectroscopy is related to both resources in the sample and in the shield, and it has caused a challenge in determination of boron concentration in the samples. In this research, various methods have been investigated to remove the effect of boron in the shield of the detector. For this purpose, Monte Carlo simulations of radiation transportation have been used. The results showed that by covering the detector shield using a cadmium sheet can greatly (99.32 %) reduce the height of the boron peak in prompt gamma spectrum recorded in the detector that come from the shield. The experiments have been done to validate the results obtained from the simulations.

Authors

Institutions

Publication Details

Journal
Heliyon
Published
2024-10-01
DOI
https://doi.org/10.1016/j.heliyon.2024.e39318
Citations
7
Primary Topic
Nuclear Physics and Applications
Type
article
Field-Weighted Citation Impact
4.25
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Improvement of detector shield in PGNAA facility for boron concentration measurement

Mostafa Jafari, J. Mokhtari, M.H. Choopan Dastjerdi, H. Jafari
7 citations
Heliyon
Nuclear Physics and Applications
4.25
article

Improvement of detector shield in PGNAA facility for boron concentration measurement

Mostafa Jafari, J. Mokhtari, M.H. Choopan Dastjerdi, H. Jafari
article en
7 citations

Abstract

A radiation shield consists of borated polyethylene (7 % wt of boron) and lead was used for the HPGe detector in Isfahan MNSR's PGNAA facility in order to remove scattered neutrons and gamma rays, respectively. Therefore, the boron peak in gamma spectroscopy is related to both resources in the sample and in the shield, and it has caused a challenge in determination of boron concentration in the samples. In this research, various methods have been investigated to remove the effect of boron in the shield of the detector. For this purpose, Monte Carlo simulations of radiation transportation have been used. The results showed that by covering the detector shield using a cadmium sheet can greatly (99.32 %) reduce the height of the boron peak in prompt gamma spectrum recorded in the detector that come from the shield. The experiments have been done to validate the results obtained from the simulations.

HeliyonVol. 10(20)
Atomic Energy Organization of Iran (IR), Nuclear Science and Technology Research Institute, Shahid Beheshti University (IR)
Openalex Percentile: Top 5%
Nuclear Physics and Applications
4.25
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Improvement of detector shield in PGNAA facility for boron concentration measurement — Mostafa Jafari, J. Mokhtari, et al. · Heliyon (2024) | TGRS Research Map | TGRS