Flexible electrodes based on laser-induced graphene as an analytical platform to monitor amoxicillin

Graphene production methods are typically complex and include micromechanical exfoliation, reduction of graphene oxide in the liquid phase, and epitaxial growth. However, a more efficient and rapid alternativeis the thermal conversion of polyimide into graphene via laser pyrolysis, offering a simpler and faster approach. Thus, this paper introduces an electrochemical platform based on laser-induced graphene generated from a visible light source to detect amoxicillin. For this purpose, a laboratory-constructed 3D-printer was utilized. In this setup, a visible laser source emitting at 449.2 nm with a maximum power output of 3.5 W was integrated into the extrusion nozzle of a fused deposition modeling 3D-printer to manufacture graphene electrodes from polyimide sheets. Subsequently, a differential pulse voltammetry method was proposed showing an oxidation peak at +0.52 V ( vs Ag|AgCl|KCl (sat.) ). The sensor exhibited a wide linear working range from 9.60 to 103.3 µmol L −1 , a limit of detection of 4.9 μmol L −1 , adequate precision (RSD < 7%), and recovery values of 90% to 107% when applied to milk samples, synthetic urine, and pharmaceutical formulations. The sensor is free from interference with other drugs commonly used in human and veterinary medicine. Herein, we report for the first time a robust, scalable, and inexpensive sensor based on a flexible substrate for the detection of amoxicillin in different matrices. It stands as an accessible possibility for routine analysis in clinical and pharmaceutical contexts.

Authors

Institutions

Publication Details

Journal
Electrochimica Acta
Published
2024-10-12
DOI
https://doi.org/10.1016/j.electacta.2024.145221
Citations
6
Primary Topic
Analytical Chemistry and Sensors
Type
article
Field-Weighted Citation Impact
1.73

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Flexible electrodes based on laser-induced graphene as an analytical platform to monitor amoxicillin

Mayane S. Carvalho, Cassiano Cunha de Souza, Wallace Burger Veríssimo de Oliveira, Osmando F. Lopes et al.
6 citations
Electrochimica Acta
Analytical Chemistry and Sensors
1.73
article

Flexible electrodes based on laser-induced graphene as an analytical platform to monitor amoxicillin

Mayane S. Carvalho, Cassiano Cunha de Souza, Wallace Burger Veríssimo de Oliveira, Osmando F. Lopes, Raylla Santos Oliveira, Thalles Pedrosa Lisboa, Renato Camargo Matos, Rodrigo A.A. Muñoz, Maria Auxiliadora Costa Matos
article en
6 citations

Abstract

Graphene production methods are typically complex and include micromechanical exfoliation, reduction of graphene oxide in the liquid phase, and epitaxial growth. However, a more efficient and rapid alternativeis the thermal conversion of polyimide into graphene via laser pyrolysis, offering a simpler and faster approach. Thus, this paper introduces an electrochemical platform based on laser-induced graphene generated from a visible light source to detect amoxicillin. For this purpose, a laboratory-constructed 3D-printer was utilized. In this setup, a visible laser source emitting at 449.2 nm with a maximum power output of 3.5 W was integrated into the extrusion nozzle of a fused deposition modeling 3D-printer to manufacture graphene electrodes from polyimide sheets. Subsequently, a differential pulse voltammetry method was proposed showing an oxidation peak at +0.52 V ( vs Ag|AgCl|KCl (sat.) ). The sensor exhibited a wide linear working range from 9.60 to 103.3 µmol L −1 , a limit of detection of 4.9 μmol L −1 , adequate precision (RSD < 7%), and recovery values of 90% to 107% when applied to milk samples, synthetic urine, and pharmaceutical formulations. The sensor is free from interference with other drugs commonly used in human and veterinary medicine. Herein, we report for the first time a robust, scalable, and inexpensive sensor based on a flexible substrate for the detection of amoxicillin in different matrices. It stands as an accessible possibility for routine analysis in clinical and pharmaceutical contexts.

Electrochimica ActaVol. 508
Universidade Federal de Juiz de Fora (BR), Universidade Federal da Grande Dourados (BR), Universidade Federal de Uberlândia (BR)
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior, Conselho Nacional de Desenvolvimento Científico e Tecnológico, Fundação de Amparo à Pesquisa do Estado de Minas Gerais
Openalex Percentile: Top 17%
Analytical Chemistry and Sensors
1.73
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.