Diode Laser Frenectomy as a Safe and Effective Surgical Option for Lingual Ankyloglossia: A Case Report

A high-power diode laser (808 nm) is a potentially cost-effective, effective, and safe option for lingual frenectomies. An eight-year-old female patient with mild difficulty in articulating some phonemes, Angle class III malocclusion with maxillary atresia, and bilateral anterior and posterior crossbite was indicated for diode laser frenectomy. The procedure was performed with the following parameters: λ = 808 nm (±20 nm), 1.5 W, in continuous mode. Energy delivery utilized a 300 μm-diameter quartz fiber maintained in contact with the irradiated tissue. A four-year follow-up revealed the preservation of tongue anatomy functionality, restored in conjunction with speech therapy. A high-power diode laser (808 nm) stands out as a prioritized alternative among available technologies for lingual frenectomy, particularly when administered by adequately trained professionals.

Authors

Institutions

Publication Details

Journal
Cureus
Published
2024-10-11
DOI
https://doi.org/10.7759/cureus.71283
Primary Topic
Oral and Craniofacial Lesions
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Diode Laser Frenectomy as a Safe and Effective Surgical Option for Lingual Ankyloglossia: A Case Report

Danielle Santos-Rodrigues, Luciane Hiramatsu Azevedo
Cureus
Oral and Craniofacial Lesions
article

Diode Laser Frenectomy as a Safe and Effective Surgical Option for Lingual Ankyloglossia: A Case Report

Danielle Santos-Rodrigues, Luciane Hiramatsu Azevedo
article en

Abstract

A high-power diode laser (808 nm) is a potentially cost-effective, effective, and safe option for lingual frenectomies. An eight-year-old female patient with mild difficulty in articulating some phonemes, Angle class III malocclusion with maxillary atresia, and bilateral anterior and posterior crossbite was indicated for diode laser frenectomy. The procedure was performed with the following parameters: λ = 808 nm (±20 nm), 1.5 W, in continuous mode. Energy delivery utilized a 300 μm-diameter quartz fiber maintained in contact with the irradiated tissue. A four-year follow-up revealed the preservation of tongue anatomy functionality, restored in conjunction with speech therapy. A high-power diode laser (808 nm) stands out as a prioritized alternative among available technologies for lingual frenectomy, particularly when administered by adequately trained professionals.

CureusVol. 16(10)
Universidade de São Paulo (BR), Universidade Cidade de São Paulo (BR), Universidade São Francisco (BR)
Australian Government, Coordenação de Aperfeiçoamento de Pessoal de Nível Superior
Quality Education
Openalex Percentile: Top 71%
Oral and Craniofacial Lesions
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.