CoFe-MOF nanoarray as flexible microelectrode for electrochemical detection of catechol in water samples

A simple, selective, and straightforward enzyme-free electrochemical sensor has been designed and developed using cobalt hexacyanoferrate metal-organic framework (CoFe-MOF) nanoarray. The prepared CoFe-MOF nanoarray has been successfully grown over a carbon cloth (CC) to form CoFe-MOF/CC as a flexible microelectrode for the detection of catechol. The surface of the activated CC was covered uniformly with CoFe-MOF in the form of nanoarray and exhibited double-shelled cubic morphology. The CoFe-MOF/CC nanoarray microelectrode showed a pair of well-defined redox peaks corresponding to the [Fe(CN)<sub>6</sub>]<sup>4-/3-</sup> redox signal. Interestingly, the fabricated nanoarray microelectrode has displayed superior peak current at lower onset potential with high electrochemical response compared to unmodified potassium hexacyanoferrate (K<sub>3</sub> [Fe(CN)<sub>6</sub>]) over CC microelectrode and bare activated CC. Further, the developed CoFe-MOF/CC nanoarray microelectrode for the oxidation of catechol was examined with consecutive injections of catechol. A fast and noticeable improvement in oxidation peak current was observed, thus representing the excellent electrocatalytic oxidation of catechol at the modified nanoarray microelectrode. Besides, CoFe-MOF/CC microelectrode exhibits an excellent linear response over a concentration range from 0.005 to 2.8 mM with low detection limit (LOD) and high sensitivity of 0.002 mM (S/N = 3) and 205.99 μA/mM, respectively. Moreover, the prepared nonenzymatic sensor showed outstanding stability, acceptable reproducibility, and repeatability, along with good interference ability. Catechol in spiked water samples was successfully quantified.

Authors

Institutions

Publication Details

Journal
Heliyon
Published
2024-10-01
DOI
https://doi.org/10.1016/j.heliyon.2024.e39241
Citations
4
Primary Topic
Electrochemical sensors and biosensors
Type
article
Field-Weighted Citation Impact
0.83

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

CoFe-MOF nanoarray as flexible microelectrode for electrochemical detection of catechol in water samples

Keehoon Won, Raji Atchudan, Mari Elancheziyan, P. Muthirulan et al.
4 citations
Heliyon
Electrochemical sensors and biosensors
0.83
article

CoFe-MOF nanoarray as flexible microelectrode for electrochemical detection of catechol in water samples

Keehoon Won, Raji Atchudan, Mari Elancheziyan, P. Muthirulan, Devaraj Manoj, Deivasigamani Ranjith Kumar, S. Arivuselvan, Elangovan Sivasurya, S. Philominamary
article en
4 citations

Abstract

A simple, selective, and straightforward enzyme-free electrochemical sensor has been designed and developed using cobalt hexacyanoferrate metal-organic framework (CoFe-MOF) nanoarray. The prepared CoFe-MOF nanoarray has been successfully grown over a carbon cloth (CC) to form CoFe-MOF/CC as a flexible microelectrode for the detection of catechol. The surface of the activated CC was covered uniformly with CoFe-MOF in the form of nanoarray and exhibited double-shelled cubic morphology. The CoFe-MOF/CC nanoarray microelectrode showed a pair of well-defined redox peaks corresponding to the [Fe(CN)<sub>6</sub>]<sup>4-/3-</sup> redox signal. Interestingly, the fabricated nanoarray microelectrode has displayed superior peak current at lower onset potential with high electrochemical response compared to unmodified potassium hexacyanoferrate (K<sub>3</sub> [Fe(CN)<sub>6</sub>]) over CC microelectrode and bare activated CC. Further, the developed CoFe-MOF/CC nanoarray microelectrode for the oxidation of catechol was examined with consecutive injections of catechol. A fast and noticeable improvement in oxidation peak current was observed, thus representing the excellent electrocatalytic oxidation of catechol at the modified nanoarray microelectrode. Besides, CoFe-MOF/CC microelectrode exhibits an excellent linear response over a concentration range from 0.005 to 2.8 mM with low detection limit (LOD) and high sensitivity of 0.002 mM (S/N = 3) and 205.99 μA/mM, respectively. Moreover, the prepared nonenzymatic sensor showed outstanding stability, acceptable reproducibility, and repeatability, along with good interference ability. Catechol in spiked water samples was successfully quantified.

HeliyonVol. 10(20)
Silesian University of Technology (PL), Dongguk University (KR), Department of Biotechnology (IN), Bharathidasan University (IN), Yeungnam University (KR), Karpagam Academy of Higher Education (IN), Saveetha University (IN)
Karpagam Academy of Higher Education
Clean water and sanitation
Openalex Percentile: Top 26%
Electrochemical sensors and biosensors
0.83
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.