Comparison of the Inadequacies of Ultrasonography and Computed Tomography in the Diagnosis of Sialolithiasis

This study aimed to determine the value of either ultrasonography and computed tomography (CT) alone or both for diagnosing salivary gland stones. Based on their clinical findings and physical examination, 188 patients with salivary stones were included. Initially, an ultrasound was performed, and then a non-contrast-enhanced thin-sliced CT scan was done. The study included 161 patients with suspected submandibular gland (SMG) sialolithiasis and 27 with parotid gland (PG) sialolithiasis. Among the SMG cases, stones were confirmed in 130 patients through interventional sialoendoscopy. Sixteen of the stones were detected by CT scan only and were not seen in the previous ultrasound examination. After the second follow-up ultrasound, which was conducted after reviewing the CT scans, 9 of them were identified. Five patients with distal stones and ductal dilation on ultrasound were confirmed to have sialolithiasis. In 5 patients with stones detected on ultrasound but not on CT, dental filling artifacts were identified as the cause. For PG cases, stones were observed in 18 out of 19 patients with suspected sialolithiasis based on ultrasound and CT findings. Three patients with positive CT findings but negative ultrasound showed stones during sialendoscopy. During an ultrasound examination, palpating the floor of the mouth with the other hand's index finger can help identify stones obscured by the shadow of the mandible, thereby enhancing the test's accuracy. Patients with dental fillings, implants, and permanent dentures should not be referred for a CT scan to avoid unnecessary exposure to ionizing radiation. They also cause significant metallic artifacts in the field of interest. In these cases, ultrasound should be considered. To minimize the effects of ionizing radiation, it is recommended to create limited field requests for the target, focusing solely on the submandibular and PGs.

Authors

Institutions

Publication Details

Journal
Ear Nose & Throat Journal
Published
2024-10-11
DOI
https://doi.org/10.1177/01455613241287291
Citations
5
Primary Topic
Salivary Gland Tumors Diagnosis and Treatment
Type
article
Field-Weighted Citation Impact
2.86
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Comparison of the Inadequacies of Ultrasonography and Computed Tomography in the Diagnosis of Sialolithiasis

Elvin Alaskarov, Husam Vehbi, Necdet Özçelіk
5 citations
Ear Nose & Throat Journal
Salivary Gland Tumors Diagnosis and Treatment
2.86
article

Comparison of the Inadequacies of Ultrasonography and Computed Tomography in the Diagnosis of Sialolithiasis

Elvin Alaskarov, Husam Vehbi, Necdet Özçelіk
article en
5 citations

Abstract

This study aimed to determine the value of either ultrasonography and computed tomography (CT) alone or both for diagnosing salivary gland stones. Based on their clinical findings and physical examination, 188 patients with salivary stones were included. Initially, an ultrasound was performed, and then a non-contrast-enhanced thin-sliced CT scan was done. The study included 161 patients with suspected submandibular gland (SMG) sialolithiasis and 27 with parotid gland (PG) sialolithiasis. Among the SMG cases, stones were confirmed in 130 patients through interventional sialoendoscopy. Sixteen of the stones were detected by CT scan only and were not seen in the previous ultrasound examination. After the second follow-up ultrasound, which was conducted after reviewing the CT scans, 9 of them were identified. Five patients with distal stones and ductal dilation on ultrasound were confirmed to have sialolithiasis. In 5 patients with stones detected on ultrasound but not on CT, dental filling artifacts were identified as the cause. For PG cases, stones were observed in 18 out of 19 patients with suspected sialolithiasis based on ultrasound and CT findings. Three patients with positive CT findings but negative ultrasound showed stones during sialendoscopy. During an ultrasound examination, palpating the floor of the mouth with the other hand's index finger can help identify stones obscured by the shadow of the mandible, thereby enhancing the test's accuracy. Patients with dental fillings, implants, and permanent dentures should not be referred for a CT scan to avoid unnecessary exposure to ionizing radiation. They also cause significant metallic artifacts in the field of interest. In these cases, ultrasound should be considered. To minimize the effects of ionizing radiation, it is recommended to create limited field requests for the target, focusing solely on the submandibular and PGs.

Ear Nose & Throat JournalVol. 103(3_suppl)
Istanbul Medipol University (TR)
Good health and well-being
Openalex Percentile: Top 9%
Salivary Gland Tumors Diagnosis and Treatment
2.86
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.