A fault detection and location algorithm for the LVDC interconnection network in rural area

Abstract Low voltage DC (LVDC) microgrids (MGs) can be linked together through an interconnection network to enhance the utilization of their energy resources in remote locations, particularly in rural low‐income areas. However, the identification of the fault is challenging due to the fast fault transients and equipment limitations, where there are no sensors and DC circuit breakers (DCCBs) in the lines. To solve this problem, this article proposes a fault detection and location algorithm without requiring extra sensors and DCCBs in lines. The proposed algorithm uses the sensors of the interface converters to detect the fault. Following this, a coordinated current injection method is used to identify the faulty element by coordinating converters with disconnectors. This process employs two strategies “weight check” and “scope check” to minimize the time and the number of actions. The algorithm is robust to various fault impedance, fault types and network topology modifications. The effectiveness of the algorithm is validated through a series of simulation case studies.

Authors

Institutions

Publication Details

Journal
IET Generation Transmission & Distribution
Published
2024-10-11
DOI
https://doi.org/10.1049/gtd2.13293
Citations
1
Primary Topic
HVDC Systems and Fault Protection
Type
article
Field-Weighted Citation Impact
0.21

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

A fault detection and location algorithm for the LVDC interconnection network in rural area

Qiteng Hong, Adrià Junyent‐Ferré, Chengwei Liu, Joan-Marc Rodriguez-Bernuz et al.
1 citations
IET Generation Transmission & Distribution
HVDC Systems and Fault Protection
0.21
article

A fault detection and location algorithm for the LVDC interconnection network in rural area

Qiteng Hong, Adrià Junyent‐Ferré, Chengwei Liu, Joan-Marc Rodriguez-Bernuz, Saizhao Yang, Di Liu, Yitong Li
article en
1 citations

Abstract

Abstract Low voltage DC (LVDC) microgrids (MGs) can be linked together through an interconnection network to enhance the utilization of their energy resources in remote locations, particularly in rural low‐income areas. However, the identification of the fault is challenging due to the fast fault transients and equipment limitations, where there are no sensors and DC circuit breakers (DCCBs) in the lines. To solve this problem, this article proposes a fault detection and location algorithm without requiring extra sensors and DCCBs in lines. The proposed algorithm uses the sensors of the interface converters to detect the fault. Following this, a coordinated current injection method is used to identify the faulty element by coordinating converters with disconnectors. This process employs two strategies “weight check” and “scope check” to minimize the time and the number of actions. The algorithm is robust to various fault impedance, fault types and network topology modifications. The effectiveness of the algorithm is validated through a series of simulation case studies.

IET Generation Transmission & DistributionVol. 18(24)
University of Strathclyde (GB), Imperial College London (GB), Huazhong University of Science and Technology (CN), Xi'an Jiaotong University (CN), Universitat Politècnica de Catalunya (ES)
Engineering and Physical Sciences Research Council
No poverty
Openalex Percentile: Top 47%
HVDC Systems and Fault Protection
0.21
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.