Just-in-Time Generation of Nanolabels via In Situ Biomineralization of ZIF-8 Enabling Ultrasensitive MicroRNA Detection on Unmodified Electrodes

Nanolabels can enhance the detection performance of electrochemical biosensing methods, yet their practical application is hindered by complex preparation, batch-to-batch variability, and poor long-term storage stability. Herein, we present a novel electrochemical method for miRNA detection based on the just-in-time generation of zeolitic imidazolate framework-8 (ZIF-8) nanolabels initiated by nucleic acids. In this design, the target miRNA-21 is captured with magnetic beads and polyadenylated by <i>Escherichia coli</i> Poly(A) polymerase (<i>E</i>PP), producing miRNA-21 molecules with poly(A) tails (miR-21-poly(A)). These molecules are then adsorbed onto a bare gold electrode (AuE) surface via adenine-gold affinity interactions, serving as nucleation sites for the rapid <i>in situ</i> formation of ZIF-8 nanoparticles. The ZIF-8 nanoparticles function as signal labels, impeding electron transfer at the electrode interfaces and thereby generating a notable electrochemical signal. The developed method demonstrated exceptional sensitivity, with a detection limit (LOD) as low as 2.3 aM and a linear detection range from 10 aM to 1000 fM. The practical application of the developed method was validated by using it to evaluate miRNA-21 expression levels in various biological samples, including cell lines, tumor tissues, and clinical blood samples from non-small cell lung cancer (NSCLC) patients. This approach simplifies the detection process by eliminating the need for presynthesized nanomaterials and premodified electrodes. Its simplicity and high sensitivity make this method a promising tool for point-of-care testing and a wide range of biomedical research applications.

Authors

Institutions

Publication Details

Journal
Analytical Chemistry
Published
2024-10-11
DOI
https://doi.org/10.1021/acs.analchem.4c03434
Citations
7
Primary Topic
Advanced biosensing and bioanalysis techniques
Type
article
Field-Weighted Citation Impact
1.64

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Just-in-Time Generation of Nanolabels via In Situ Biomineralization of ZIF-8 Enabling Ultrasensitive MicroRNA Detection on Unmodified Electrodes

Yiwen Pan, Haiyan Dong, Dayun Yang, R. Stephanie Huang et al.
7 citations
Analytical Chemistry
Advanced biosensing and bioanalysis techniques
1.64
article

Just-in-Time Generation of Nanolabels via In Situ Biomineralization of ZIF-8 Enabling Ultrasensitive MicroRNA Detection on Unmodified Electrodes

Yiwen Pan, Haiyan Dong, Dayun Yang, R. Stephanie Huang, Junyang Zhuang, Ning Li, Xi Lin, Baoquan Lin, Zhao Guo, Jia Zhao, Yang Yang
article en
7 citations

Abstract

Nanolabels can enhance the detection performance of electrochemical biosensing methods, yet their practical application is hindered by complex preparation, batch-to-batch variability, and poor long-term storage stability. Herein, we present a novel electrochemical method for miRNA detection based on the just-in-time generation of zeolitic imidazolate framework-8 (ZIF-8) nanolabels initiated by nucleic acids. In this design, the target miRNA-21 is captured with magnetic beads and polyadenylated by <i>Escherichia coli</i> Poly(A) polymerase (<i>E</i>PP), producing miRNA-21 molecules with poly(A) tails (miR-21-poly(A)). These molecules are then adsorbed onto a bare gold electrode (AuE) surface via adenine-gold affinity interactions, serving as nucleation sites for the rapid <i>in situ</i> formation of ZIF-8 nanoparticles. The ZIF-8 nanoparticles function as signal labels, impeding electron transfer at the electrode interfaces and thereby generating a notable electrochemical signal. The developed method demonstrated exceptional sensitivity, with a detection limit (LOD) as low as 2.3 aM and a linear detection range from 10 aM to 1000 fM. The practical application of the developed method was validated by using it to evaluate miRNA-21 expression levels in various biological samples, including cell lines, tumor tissues, and clinical blood samples from non-small cell lung cancer (NSCLC) patients. This approach simplifies the detection process by eliminating the need for presynthesized nanomaterials and premodified electrodes. Its simplicity and high sensitivity make this method a promising tool for point-of-care testing and a wide range of biomedical research applications.

Analytical ChemistryVol. 96(42)
Fujian Medical University (CN)
National Natural Science Foundation of China, Natural Science Foundation of Fujian Province
Openalex Percentile: Top 16%
Advanced biosensing and bioanalysis techniques
1.64
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.