Performance of the Aptis distal radioulnar joint implant: kinematic and geometric analysis

This study reviews the performance of the Aptis distal radioulnar joint arthroplasty by comparing multiple kinematic and geometric measurements in the operated and contralateral healthy forearm to elucidate whether these are altered after arthroplasty. Forearm geometry and motion were captured using 3-D and 4-D computed tomography in 12 patients with unilateral Aptis arthroplasties. After segmentation and registration, the axis of forearm rotation, translation of the radius along the ulna and range of wrist flexion-extension were measured, and the Dice coefficient and Hausdorff distance were calculated. The forearm rotation axis in the corrected arm deviated 2.3° from the healthy contralateral rotation axis, radial translation along the ulna decreased by 45% and wrist flexion-extension also decreased significantly. Multiple intra-individual geometric differences were observed. The Aptis distal radioulnar joint arthroplasty considerably alters forearm kinematics, which can have clinical implications.<b>Level of evidence:</b> IV.

Authors

Institutions

Publication Details

Journal
Journal of Hand Surgery (European Volume)
Published
2024-10-11
DOI
https://doi.org/10.1177/17531934241274142
Citations
2
Primary Topic
Orthopedic Surgery and Rehabilitation
Type
article
Field-Weighted Citation Impact
1.15

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Performance of the Aptis distal radioulnar joint implant: kinematic and geometric analysis

Shirley D. Stougie, Joris G. M. Oonk, J. Henk Coert, Geert J. Streekstra et al.
2 citations
Journal of Hand Surgery (European Volume)
Orthopedic Surgery and Rehabilitation
1.15
article

Performance of the Aptis distal radioulnar joint implant: kinematic and geometric analysis

Shirley D. Stougie, Joris G. M. Oonk, J. Henk Coert, Geert J. Streekstra, Johannes G. G. Dobbe, Marco J.P.F. Ritt
article en
2 citations

Abstract

This study reviews the performance of the Aptis distal radioulnar joint arthroplasty by comparing multiple kinematic and geometric measurements in the operated and contralateral healthy forearm to elucidate whether these are altered after arthroplasty. Forearm geometry and motion were captured using 3-D and 4-D computed tomography in 12 patients with unilateral Aptis arthroplasties. After segmentation and registration, the axis of forearm rotation, translation of the radius along the ulna and range of wrist flexion-extension were measured, and the Dice coefficient and Hausdorff distance were calculated. The forearm rotation axis in the corrected arm deviated 2.3° from the healthy contralateral rotation axis, radial translation along the ulna decreased by 45% and wrist flexion-extension also decreased significantly. Multiple intra-individual geometric differences were observed. The Aptis distal radioulnar joint arthroplasty considerably alters forearm kinematics, which can have clinical implications.<b>Level of evidence:</b> IV.

Journal of Hand Surgery (European Volume)Vol. 50(3)
University Medical Center Utrecht (NL), Amsterdam University Medical Centers (NL), University of Amsterdam (NL)
Eurostars
Openalex Percentile: Top 20%
Orthopedic Surgery and Rehabilitation
1.15
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.