Affordable and Reliable RP-HPLC Method for Verapamil Hydrochloride Quantification in Rabbit Plasma for Pharmacokinetics

Background: Existing bioanalytical methods for verapamil hydrochloride (VH) are often complex, requiring advanced instrumentation and specialized expertise, which limits their use in resource-constrained laboratories. Aim: The goal of this study is to fill this gap by developing a simplified, robust RP-HPLC-UV approach for the estimation of verapamil hydrochloride in rabbit plasma. Designed to enhance accuracy and precision while minimizing sample preparation challenges, this method addresses existing limitations by providing an affordable and reliable alternative for laboratories lacking sophisticated instrumentation. Methods: The bioanalytical method was implemented on C-18 stationary phase (5 μ, 250 × 4.6 mm) using acetonitrile/0.1% tetrahydrofuran (THF) in water (80:20, in volume) as the liquid system at a 1 mL/min flow speed, employing carvedilol as an internal standard. Results: The reported retention times of verapamil hydrochloride and carvedilol were ~7.64 and 4.69 min, respectively, at sufficiently high system suitability standards. The linearity of the bioanalytical approach can be seen between 0.025 and 5.0 µg/mL (r2 = 0.9991). The findings indicated that there was no matrix influence in terms of accuracy (≥98.96 ± 2.68%), intra- and inter-day precision (≤3.68%), recovery (101.98 ± 2.76%), and procedure efficiency (100.65 ± 1.82%). Benchtop, long-term, and short-term stability investigations all revealed that the verapamil hydrochloride in the bio-samples was stable. The pharmacokinetic parameters (Cmax—3.47 µg/mL; Tmax—1.59 h) were studied from time-dependent plasma concentrations of verapamil hydrochloride estimated after 40 mg oral dosing in New Zealand white rabbits. Conclusions: The developed bioanalytical method provided easier quantitative analysis of verapamil hydrochloride from rabbit plasma and was effectively used in a pharmacokinetic investigation of an oral bolus. The reliable performance of this method under practical conditions positions it as a crucial tool for advancing pharmacokinetic studies across various research environments.

Authors

Institutions

Publication Details

Journal
Processes
Published
2024-10-11
DOI
https://doi.org/10.3390/pr12102211
Primary Topic
Analytical Methods in Pharmaceuticals
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Affordable and Reliable RP-HPLC Method for Verapamil Hydrochloride Quantification in Rabbit Plasma for Pharmacokinetics

S Shanmuganathan, Abimanyu Sugumaran, Mona Y. Alsheikh, Raja Navamanisubramanian et al.
Processes
Analytical Methods in Pharmaceuticals
article

Affordable and Reliable RP-HPLC Method for Verapamil Hydrochloride Quantification in Rabbit Plasma for Pharmacokinetics

S Shanmuganathan, Abimanyu Sugumaran, Mona Y. Alsheikh, Raja Navamanisubramanian, Ibrahim Ahmed Naguib, Mohammed Gamal
article en

Abstract

Background: Existing bioanalytical methods for verapamil hydrochloride (VH) are often complex, requiring advanced instrumentation and specialized expertise, which limits their use in resource-constrained laboratories. Aim: The goal of this study is to fill this gap by developing a simplified, robust RP-HPLC-UV approach for the estimation of verapamil hydrochloride in rabbit plasma. Designed to enhance accuracy and precision while minimizing sample preparation challenges, this method addresses existing limitations by providing an affordable and reliable alternative for laboratories lacking sophisticated instrumentation. Methods: The bioanalytical method was implemented on C-18 stationary phase (5 μ, 250 × 4.6 mm) using acetonitrile/0.1% tetrahydrofuran (THF) in water (80:20, in volume) as the liquid system at a 1 mL/min flow speed, employing carvedilol as an internal standard. Results: The reported retention times of verapamil hydrochloride and carvedilol were ~7.64 and 4.69 min, respectively, at sufficiently high system suitability standards. The linearity of the bioanalytical approach can be seen between 0.025 and 5.0 µg/mL (r2 = 0.9991). The findings indicated that there was no matrix influence in terms of accuracy (≥98.96 ± 2.68%), intra- and inter-day precision (≤3.68%), recovery (101.98 ± 2.76%), and procedure efficiency (100.65 ± 1.82%). Benchtop, long-term, and short-term stability investigations all revealed that the verapamil hydrochloride in the bio-samples was stable. The pharmacokinetic parameters (Cmax—3.47 µg/mL; Tmax—1.59 h) were studied from time-dependent plasma concentrations of verapamil hydrochloride estimated after 40 mg oral dosing in New Zealand white rabbits. Conclusions: The developed bioanalytical method provided easier quantitative analysis of verapamil hydrochloride from rabbit plasma and was effectively used in a pharmacokinetic investigation of an oral bolus. The reliable performance of this method under practical conditions positions it as a crucial tool for advancing pharmacokinetic studies across various research environments.

ProcessesVol. 12(10)
Beni-Suef University (EG), Taif University (SA), King Abdulaziz University (SA), Sri Balaji Vidyapeeth University (IN), Assam University (IN), B.S. Abdur Rahman Crescent Institute of Science & Technology (IN)
Openalex Percentile: Top 84%
Analytical Methods in Pharmaceuticals
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.